Fip-1.36 Periodically Replaced Part - End Of Life - Epson ColorPage EPL-C8200 Service Manual

Color laser printer
Hide thumbs Also See for ColorPage EPL-C8200:
Table of Contents

Advertisement

EPSON ColorPage EPL-C8200

FIP-1.36 Periodically Replaced Part - End Of Life

Step
Check point
Perform the preliminary inspection.
1
Parts to inspect: MCU PWB
Check: Error Reset
In the Maintenance menu, perform the required counter
reset:
- 2nd BTR Reset
2
- Fuser Unit Reset
- IBT Cleaner Reset
(Refer to Chapter 6.)

Does the problem still occur after "Error Reset"?
Replace the relevant part.

3
Does the problem still occur?

4
Does the problem occur when the printer is turned on?

Does the problem still occur when the printer is turned
5
on again?

Does the problem occur when the printer is turned off
6
and on repeatedly?
Check: MCU PWB replacement
7
Replace the MCU PWB.

Does the problem still occur?
Chapter 5
Troubleshooting
Yes
Replace/reinstall the defective part(s).
Go to Step 3.
Go to Step 4.
Go to Step 7.
Go to Step 7.
Go to Step 7.
Replace the MCU PWB.
Remedy
No
Go to Step 2.
Problem solved.
Replace the relevant part.
Go to Step 5.
Go to Step 6.
Go to FIP-2.39 "Electrical Noise"
Check the Controller PWB.
Revision A
5-53