Epson ColorPage EPL-C8200 Service Manual page 318

Color laser printer
Hide thumbs Also See for ColorPage EPL-C8200:
Table of Contents

Advertisement

EPSON ColorPage EPL-C8200
(1) Commands
Table 4-62. Command List of the Parameter Control (1/2)
Command
Command
code (Hex)
LIFCNTSET #
80
LIFLIMSET #
81
LIFDEF #
82
TIMSET #
83
TIMDEF #
84
CTLSET #
85
CTLDEF #
86
STSSET #
87
LIFWNGSET #
88
LIFWNGDEF #
89
LIFCNTR
D0
LIFLIMR
D1
TIMSETR
D2
TIMUNITR
D3
Chapter 4
Diagnostics
Parameter
Description
code
1.LIFE, 2.V1,
3.V2, 4.V3,
Writes data in the life counter.
5.V4
<Do not use this command
1.LIFE, 2.V1,
unless instructed!>
3.V2, 4.V3,
5.V4
Changes the life over value.
Changes the life over value to
1.LIFE
the default.
<Do not use this command
1.TIM, 2.V1,
unless instructed!>
3.V2, 4.V3
Changes the time out value.
Changes the time-out value to
1.TIM
the default.
1.CTL, 2.V1,
Changes the control value.
3.V2, 4.V3
Changes the control value to
1.CTL
the default.
1.STC, 2.V1,
Writes data in the statistical
3.V2, 4.V3
counter.
1.LIFE, 2.V1,
<Do not use this command
3.V2, 4.V3,
unless instructed!> Changes
5.V4
the life warning value.
Changes the life warning
1.LIFE
value to the default.
1.LIFE
Reads the life counter.
1.LIFE
Reads the life over value
1.TIM
Reads the time-out value.
1.TIM
Reads the time-out unit.
Table 4-63. Command List of the Parameter Control (2/2)
Command
Parameter
Command
code (Hex)
TIMMINR
D4
1.TIM
TIMMAXR
D5
1.TIM
CTLVALR
D6
1.CTL
CTLSETR
D7
1.CTL
CTLACCSR
D8
1.CTL
CTLMINR
D9
1.CTL
CTLMAXR
DA
1.CTL
STCCNR
DB
1.STC
LIFEDEFR
DC
1.LIFE
TIMDEFR
DD
1.TIM
CTLDEFR
DE
1.CTL
LIFWNGR
F0
1.LIFE
LIFWDEFR
F1
1.LIFE
CRIDR
F2
None
CRMDR
F3
None
A command with "#" is a command without a responding status.
Note: The parameter codes V1 through V4 are in decimal. Enter a value from the
upper byte so that it can be read normally.
Revision A
Description
code
Reads the minimum time-out
value.
Reads the maximum time-out
value.
Reads the controlled value (that
changes).
Reads the control value.
Reads the privilege to access
the control value.
Reads the minimum control
value.
Reads the maximum control
value.
Reads the statistical counter.
Reads the default life-over
value.
Reads the default time-out
value.
Reads the default control value.
Reads the life warning value.
Reads the default life warning
value.
Reads the CRUM ID.
Reads the CRUM data.
4-54

Advertisement

Table of Contents
loading

Table of Contents