Parameter
name
Switching Mode
124
in Torque
Control
Gain Switching
125
Delay Time in
Torque Control
Gain Switching
126
Level in Torque
Control
Gain Switching
127
Hysteresis in
Torque Control
Note 1: The default setting is 320 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 2: The default setting is 180 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 3: The default setting is 310 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 4: The default setting is 126 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 5: The default setting is 380 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 6: The default setting is 180 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 7: The default setting is 126 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Description
Select the gain switching condition for
torque control.
It is necessary that Pn114 be set to 1.
0
Always gain 1
1
Always gain 2
Switching using gain switching input
2
(GSEL)
3
Torque command change amount
Set the delay time for switching from gain 2
to gain 1.
Set the gain switching level.
Set the hysteresis for gain switching.
12-2 Parameter List
Default
Setting
Unit
setting
range
0
0 to 3
0 to
0
0.1 ms
10,000
0 to
0
20,000
0 to
0
20,000
12-16
Power
supply
OFF to
ON
12