11-3 Alarm List
number
Main
55
87
95
99
Other
numbers
*1. An immediate stop means an alarm causing an immediate stop when the Pn510 "Stop Selection for
11
11-9
Alarm
Error detection function
Sub
Phase-A connection error
0
Phase-B connection error
1
Phase-Z connection error
2
Emergency stop input
0
error
0 to
Motor non-conformity
4
Other errors
0
Alarm Detection" is set to 4 to 7. For details, refer to "Stop Selection for Alarm Detection"(P.8-51).
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Detection details and probable
cause
An error was detected in the external
encoder phase A connection.
An error was detected in the external
encoder phase B connection.
An error was detected in the external
encoder phase Z connection.
An emergency stop input signal
(STOP) was input.
The combination of the Servomotor
and Servo Drive is not appropriate.
The control circuit malfunctioned due
to excess noise or some other
problem.
An alarm clear operation was
performed when safety input 1 or
safety input 2 was not in the normal
status (i.e., when the input
photocoupler was not ON).
Attribute
Can be
Immediate
History
cleared
stop *1
√
−
−
√
−
−
√
−
−
−
√
−
−
−
−
√
−
−