Electronic Gear Function (Pn008, Pn009, Pn010)
This function sets the position command for the position control part a value calculated by
multiplying the pulse command input from the Host Controller with the set electronic gear ratio.
Parameter
number
Electronic Gear
Pn008
Integer Setting
Electronic Gear
Pn009
Ratio Numerator 1
Electronic Gear
Pn010
Ratio
Denominator
 For details on the electronic gear function, refer to "6-4 Electronic Gear Function"(P.6-10).
 For fully-closed control, set the Electronic Gear Integer Setting (Pn008) to 0, and set the Electronic
Gear Ratio Numerator 1 (Pn009) and Electronic Gear Ratio Denominator (Pn010).
Encoder Dividing Function (Pn011, Pn012, Pn503)
The number of pulses can be set for the encoder signals output from the drive.
Parameter
number
Encoder Dividing
Pn011
Numerator
Encoder Output
Direction
Switching
Selection
Pn012
Encoder Dividing
Denominator
Pn503
 For details on encoder dividing function, refer to "6-5 Encoder Dividing Function"(P.6-14).
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Parameter name
Set the number of command pulses
corresponding to 1 motor rotation.
Set the numerator of the electronic
gear ratio for the command pulse
input.
Set the denominator of the electronic
gear ratio for the command pulse
input.
Parameter name
Set the number of phase A and
phase B output pulses, respectively
per motor rotation.
Select the phase B logic for pulse
regeneration output and the output
source. For fully-closed control,
select an external encoder for the
output source.
Set
value
0
1
2
3
When the number of output pulse per
rotation is not an integer, you can set
a dividing ratio by setting the set
value here to a number other than 0,
and using Pn011 as the dividing
numerator and Pn503 as the dividing
denominator.
5-6 Fully-closed Control
Explanation
Explanation
Output
Phase B
source
logic
Non-reverse
Encoder
Reverse
Non-reverse
External
encoder
Reverse
Setting
Unit
range
20
0 to 2
Pulse
30
0 to 2
30
1 to 2
Setting
Unit
range
1 to 262144
Pulse/r
0 to 3
0 and
1 to 262144
5-30
5

Hide quick links: