8-1 Basic Parameters
Pn003
Realtime Autotuning Machine Rigidity Setting
Setting
0 to 31
range
Default settings:
* Pn003 = 11 - For 200V drives of 1 kW or upper and 400V drives
Set the machine rigidity to one of 32 levels when realtime autotuning is enabled.
If the set value is changed suddenly by a large amount, the gain may change rapidly, subjecting
the machine to shock. Always start with a small setting, and gradually increase the setting while
monitoring machine operation.
Pn004
Inertia Ratio
Setting
0 to 10,000
range
Set the load inertia as a percentage of the motor rotor inertia.
Pn004 = (Load inertia / Rotor inertia) × 100%
When realtime autotuning is enabled, the inertia ratio is continuously estimated and saved in
EEPROM every 30 minutes.
If the inertia ratio is set correctly, the setting unit for the Speed Loop Gain (Pn101) and Speed Loop
Gain 2 (Pn106) is Hz.
If the Inertia Ratio (Pn004) is set larger than the actual value, the setting for speed loop gain will
8
increase. If the Inertia Ratio (Pn004) is set smaller than the actual value, the setting for speed loop
gain will decrease.
Pn005
Command Pulse Input Selection
Setting
0 or 1
range
Explanation of Set Values
value
0
1
Selects whether to use photocoupler or input for line driver only for the command pulse input.
When using a Servo Relay Unit cable, set to 0 (photocoupler input).
Pn006
Command Pulse Rotation Direction Switching Selection
Setting
0 or 1
range
8-3
Unit
Low
Low
Pn003
0.1 - - - - - - - - - - - - - - - 31
Low
Unit
Unit
Set
Photocoupler input (+PULS: CN1 pin 3, -PULS: CN1 pin 4, +SIGN: CN1 pin 5, -SIGN: CN1
pin 6)
Input for line driver only (+CWLD: CN1 pin 44, -CWLD: CN1 pin 45, +CCWLD: CN1 pin 46,
-CCWLD: CN1 pin 47)
Unit
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
−
setting
←Machine rigidity→
High
←Servo gain→
High
←Responsiveness→
High
Default
%
setting
Default
−
setting
Description
Default
−
setting
All
Power OFF
−
13 *
and ON
All
Power OFF
−
250
and ON
Position Fully-closed
Power OFF
0
Yes
and ON
Position Fully-closed
Power OFF
0
Yes
and ON