8-3 Vibration Suppression Parameters
Pn206
Notch 2 Depth Setting
Setting
0 to 99
range
Set the notch depth of resonance suppression notch filter 2.
Increasing the set value shortens the notch depth and the phase lag.
Pn207
Notch 3 Frequency Setting
Setting
50 to 5,000
range
Set the notch frequency of resonance suppression notch filter 3.
The notch filter function will be disabled if this parameter is set to 5,000.
Pn208
Notch 3 Width Setting
Setting
0 to 20
range
Select the notch width of resonance suppression notch filter 3.
Increasing the set value widens the notch width. Normally, use the default set value.
Pn209
Notch 3 Depth Setting
Setting
0 to 99
range
Set the notch depth of resonance suppression notch filter 3.
Increasing the set value shortens the notch depth and the phase lag.
Pn210
Notch 4 Frequency Setting
8
Setting
50 to 5,000
range
Set the notch frequency of resonance suppression notch filter 4.
The notch filter function will be disabled if this parameter is set to 5,000.
Pn211
Notch 4 Width Setting
Setting
0 to 20
range
Select the notch width of resonance suppression notch filter 4.
Increasing the set value widens the notch width. Normally, use the default set value.
Pn212
Notch 4 Depth Setting
Setting
0 to 99
range
Set the notch depth of resonance suppression notch filter 4.
Increasing the set value shortens the notch depth and the phase lag.
Pn213
Damping Filter Selection
Setting
0 to 3
range
8-21
−
Unit
Unit
Hz
−
Unit
−
Unit
Unit
Hz
−
Unit
−
Unit
−
Unit
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
Power OFF
0
setting
and ON
Default
Power OFF
5000
setting
and ON
Default
Power OFF
2
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
5000
setting
and ON
Default
Power OFF
2
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
All
−
All
−
All
−
All
−
All
−
All
−
All
−
Position
−