4-1 Installation Conditions
 Depending on the environment, such as when the Servomotor is installed near a heating element,
the Servomotor temperature may rise significantly. In this case, take any of the following
measures.
Other Precautions
 Take measures to protect the motor shaft from corrosion. The motor shaft is coated with anti-
corrosion oil when shipped, but anti-corrosion oil or grease should also be applied when
connecting the components that apply load to the shaft.
4
4-5
Lower the load ratio.
Review the heat radiation conditions of the Servomotor.
Install a cooling fan and apply forced air cooling to the Servomotor.
Do not apply a commercial power supply
directly to the motor. Failure may result.
Never repair the Servo Drive by disassembling it.
Electric shock or injury may result.