Explanation of Set Values
Set
value
0
Damping filter 1 and 2 enabled
With external input (DFSEL1), either 1 and 3 or 2 and 4 can be selected.
1
· Open: Damping filters 1 and 3 enabled
· Shorted: Damping filters 2 and 4 enabled
With external input (DFSEL1 and DFSEL2), one of the filters 1 to 4 can be selected.
· When DFSEL1 and DFSEL2 are both open: Damping filter 1 enabled
2
· When DFSEL1 is shorted and DFSEL2 is open: Damping filter 2 enabled
· When DFSEL1 is open and DFSEL2 is shorted: Damping filter 3 enabled
· When DFSEL1 and DFSEL2 are both shorted: Damping filter 4 enabled
The damping filters are switched with position command direction.
3
· Forward direction: Damping filters 1 and 3 enabled
· Reverse direction: Damping filters 2 and 4 enabled
Pn214
Damping Frequency 1
Setting
0 to 2,000
range
Set damping frequency 1 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
The range of frequency setting is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9
Hz.
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
Pn215
Damping Filter 1 Setting
Setting
0 to 1,000
range
First set the Damping Frequency 1 (Pn214). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
Set value is restricted in the following manner.
Upper limit: Corresponding damping frequency
Lower limit: Damping frequency + damping filter setting ≥ 100
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
Pn216
Damping Frequency 2
Setting
0 to 2,000
range
Set Damping Frequency 2 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
The range of frequency setting is 1.0 to 200.0 Hz. The function is disabled if the setting is 0 to 0.9
Hz.
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
Pn217
Damping Filter 2 Setting
Setting
0 to 1,000
range
First set the Damping Frequency 2 (Pn216). Then reduce the setting if torque saturation occurs
or increase the setting to increase operation speed. Normally, use a setting of 0.
Set value is restricted in the following manner.
Upper limit: Corresponding damping frequency
Lower limit: Damping frequency + damping filter setting ≥ 100
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8-3 Vibration Suppression Parameters
Description
Unit
0.1 Hz
Unit
0.1 Hz
Unit
0.1 Hz
Unit
0.1 Hz
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Position
−
Position
8
−
Position
−
Position
−
8-22