Pn435
Speed Conformity Detection Range
Setting
10 to 20,000
range
When speed command and motor speed are identical, speed conformity output signal is output.
This setting has a hysteresis of 10 r/min for detection.
Speed command
Speed [r/min]
Pn435
Speed Conformity
Detection Range
Speed conformity
ON
output
Pn436
Rotation Speed for Motor Rotation Detection
Setting
10 to 20,000
range
Motor rotation speed detection output signal is output when the motor speed reaches the speed
set as the achieved speed.
This setting has a hysteresis of 10 r/min for detection.
Speed [r/min]
Pn436+10
Pn436−10
− (Pn436−10)
− (Pn436+10)
Motor rotation speed
OFF
detection output
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8-5 Interface Monitor Setting Parameters
Unit
r/min
A speed command after the acceleration
/deceleration processing
Motor speed
Speed Conformity Detection Range
OFF
ON
Unit
r/min
Motor speed
ON
OFF
Default
Power OFF
50
setting
and ON
Pn435
Speed Conformity Detection Range
Pn435
OFF
Default
Power OFF
1000
setting
and ON
ON
Speed
−
Time
Speed
−
8
Time
8-44