Advertisement

Pn435
Speed Conformity Detection Range
Setting
10 to 20,000
range
 When speed command and motor speed are identical, speed conformity output signal is output.
This setting has a hysteresis of 10 r/min for detection.
Speed command
Speed [r/min]
Pn435
Speed Conformity
Detection Range
Speed conformity
ON
output
Pn436
Rotation Speed for Motor Rotation Detection
Setting
10 to 20,000
range
 Motor rotation speed detection output signal is output when the motor speed reaches the speed
set as the achieved speed.
This setting has a hysteresis of 10 r/min for detection.
Speed [r/min]
Pn436+10
Pn436−10
− (Pn436−10)
− (Pn436+10)
Motor rotation speed
OFF
detection output
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8-5 Interface Monitor Setting Parameters
Unit
r/min
A speed command after the acceleration
/deceleration processing
Motor speed
Speed Conformity Detection Range
OFF
ON
Unit
r/min
Motor speed
ON
OFF
Default
Power OFF
50
setting
and ON
Pn435
Speed Conformity Detection Range
Pn435
OFF
Default
Power OFF
1000
setting
and ON
ON
Speed
Time
Speed
8
Time
8-44