3-1 Servo Drive Specifications
R88D-KT150H
Terminal Block Specifications, Top Terminal Block (TB1)
Symbol
L1C
L2C
DB1
DB2
Terminal Block Specifications, Bottom Terminal Block (TB2)
3
Symbol
L1
L2
L3
B1
B2
N (NC)
U
V
W
 Tighten the terminal block screws to the torque of 1.5 N•m (M5) or 2.5 N•m (M6).
 If the torque for terminal block screws exceeds 2.0 N•m (M5) or 3.0 N•m (M6), the terminal block
may be damaged.
 Tighten the fixing screw of the terminal block cover to the torque of 0.4 N•m (M5).
 Tighten the ground screws to the torque of 2.4 to 2.6 N•m (M6).
 Never connect an External Regeneration Resistor between the B1 and N (NC) terminals
3-13
Name
Control circuit power
supply input
Dynamic brake
resistance control
terminals
Name
Main circuit power supply
input
External Regeneration
Resistor connection
terminals
Motor connection
terminals
Frame ground
Precautions for Correct Use
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
R88D-KT@H: Single-phase 200 to 230 VAC (170 to 253 V) 50/60
Hz
280 to 325 VDC (238 to 357 VDC)
These terminals are used to control the MC for externally connected
dynamic brake resistance. The output contact specifications are
1 A max. at 300 VAC/100 VDC max. Connect them if required.
R88D-KT@H (15 kW): 3-phase 200 to 230 VAC (170 to 253 V) 50/
60 Hz
280 to 325 VDC (238 to 357 VDC)
Connect an External Regeneration Resistor between B1 and B2.
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
This is the ground terminal. Ground to 100 Ω or less.
Function
Function

Hide quick links:

Advertisement

loading