Omron R88D-KTA5L User Manual page 487

Ac servomotors/servo drives

Advertisement

Pn507
Stop Selection with Main Power Supply OFF
Setting
0 to 9
range
Explanation of Set Values
Set
value
0
Dynamic brake operation
1
Free-run
2
Dynamic brake operation
3
Free-run
4
Dynamic brake operation
5
Free-run
6
Dynamic brake operation
7
Free-run
8
Immediate stop *
9
Immediate stop *
 If an alarm occurs when the main power supply is turned OFF, the operation will be based on the Stop
Selection for Alarm Detection (Pn510). If the main power supply is turned OFF when Servo is ON,
and if the Undervoltage Alarm Selection (Pn508) is set to 1, Alarm 13.1, "main power supply
undervoltage (AC cut-off detection)," will occur. Follow the Stop Selection for Alarm Detection
(Pn510).
The dynamic brake is designed only for emergency stopping. Design the system to stop within
about ten minutes after the dynamic brake operates.
*1. Emergency stop refers to an immediate stop operation applying control while servo is still ON and stopping
the operation immediately.
At that time, the torque command value is restricted by the Immediate Stop Torque (Pn511).
*2. If the position command is given or the motor runs continuously when the main power supply is turned OFF, the
position error accumulates and Alarm 24.0, "error counter overflow," may occur. In addition, if servo is turned ON when
the position error or external encoder error is a large value, the motor may operate abruptly to perform a control
operation to bring the error to 0. Take sufficient care when using while holding the position error or external encoder
error.
*3. Decelerating is the time between when the motor is running and when the motor speed reaches 30 r/
min or less. Once the motor reaches 30 r/min or less and moves to the after-stop status, subsequent
operation is based on the after-stop status regardless of the motor speed.
*4. The position error or external encoder error will always be cleared to 0.
Pn508
Undervoltage Alarm Selection
Setting
0 or 1
range
Explanation of Set Values
Set value
The servo is turned OFF based on the setting of the Stop Selection with Main Power Supply
0
OFF (Pn507) and turn it back to servo ON state by turning ON the main power supply.
1
Alarm 13.1 "main power supply undervoltage" will occur and a trip will be caused.
Pn509
Momentary Hold Time
Setting
70 to 2,000
range
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
3
During deceleration *
1
1
Unit
Unit
1 ms
8-6 Extended Parameters
Default
0
setting
Explanation
After stopping
Dynamic brake operation
Dynamic brake operation
Servo free
Servo free
Dynamic brake operation
Dynamic brake operation
Servo free
Servo free
Dynamic brake operation
Servo free
Default
1
setting
Description
Default
70
setting
All
Power OFF
and ON
Error counter
4
Clear *
4
Clear *
4
Clear *
4
Clear *
2
Hold *
2
Hold *
2
Hold *
2
Hold *
4
Clear *
4
Clear *
All
Power OFF
and ON
All
Power OFF
Yes
and ON
8-50
8