Log Messages - ZyXEL Communications Multi-service Access Platform MSAP2000 User Manual

Adsl access module 12-port adsl2+ multiplexer network module
Table of Contents

Advertisement

MSAP2000 AAMS User's Guide

21.2.1 Log Messages

The following table lists and describes the system log messages.
Table 54
LOG MESSAGE
ADSL <port> Link
Up(SN=<seq no>):
<ds rate>/<us
rate>!
or
ADSL Link Info:
NM:<ds NM>/<us
NM>!
ADSL <port> Link
Down(SN=<seq no>)!
Session Begin!
Session End!
Incorrect
Password!
Received Firmware
Checksum Error!
Received Firmware
Size too large!
Received Firmware
Invalid!
Received File
<file>!
THERMO OVER
TEMPERATURE:
dev:<id>
threshold:<thresho
ld>(degree C)
value:<temp>(degre e
C)!
THERMO OVER
TEMPERATURE
released: dev:<id>
threshold:<thresho
ld>(degree C)
value:<temp>(degre e
C)!
Log Messages
TYPE
INFO
WARN
INFO
INFO
WARN
WARN
firmware upload.
WARN
WARN
INFO
WARN
INFO
DESCRIPTION
An ADSL port established a connection.
<port>
- port number
<seq no>
- sequence number of the connection
<ds rate>
- downstream rate
<us rate>
- upstream rate
<us NM>
- upstream noise margin
<ds NM>
- downstream noise margin
An ADSL port lost its connection.
<port>
- port number
A console, telnet or FTP session has begun (see the
<process> field for the type of session).
A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Someone attempted to use the wrong password to start a
console, telnet or FTP session (see the <process> field for
the type of session).
A checksum error was detected during an attempted FTP
The file size was too large with an attempted FTP
firmware upload.
Someone attempted to upload a firmware file with a
wrong identity via FTP.
A file was uploaded to the MSAP2000 AAMS by FTP.
<file>
- received file's name.
The temperature was too high at one of the temperature
sensors.
<id>
- 0: sensor near the ADSL chipset
- 1: sensor near the CPU
- 2: thermal sensor chip itself
<threshold>
- threshold temperature
<temp>
- temperature when the entry was logged
The temperature at one of the temperature sensors has
come back to normal.
<id>
- 0: sensor near the ADSL chipset
- 1: sensor near the CPU
- 2: thermal sensor chip itself
<threshold>
- threshold temperature
<temp>
- temperature when the entry was logged