MSAP2000 AAMS User's Guide
Table 9
LABEL
Temperature
Current
MAX
MIN
Average
Threshold (Low)
Threshold (Hi)
Status
Voltage
Current
MAX
MIN
Average
Threshold (Low)
Threshold (Hi)
Status
Use this section of the screen to configure the hardware monitor threshold settings.
New threshold
Temperature (Hi)
Temperature
(Low)
Volt. (Hi)
Volt. (Low)
Poll Interval(s)
Stop

6.3 General Setup

Click Basic Setting and General Setup in the navigation panel to display the
screen as shown.
System Information (continued)
DESCRIPTION
Each temperature sensor can detect and report the temperature. Temperature
sensor 1 is near the ADSL line driver. Temperature sensor 2 is near the ADSL
chipset. Temperature sensor 3 is near the central processing unit.
This shows the current temperature at this sensor.
This field displays the maximum temperature measured at this sensor.
This field displays the minimum temperature measured at this sensor.
This field displays the average temperature measured at this sensor.
This field displays the lowest temperature limit at this sensor.
This field displays the highest temperature limit at this sensor.
This field displays Normal for temperatures below the threshold and Over
for those above.
The power supply for each voltage has a sensor that can detect and report
the voltage.
This is the current voltage reading.
This field displays the maximum voltage measured at this point.
This field displays the minimum voltage measured at this point.
This field displays the average voltage measured at this sensor.
This field displays the lowest voltage limit at this sensor.
This field displays the highest voltage limit at this sensor.
Normal indicates that the voltage is within an acceptable operating range at
this point; otherwise Abnormal is displayed.
Configure new threshold settings in the fields below and click Apply to use them.
Use these fields to configure the highest temperature limit at each sensor
Use these fields to configure the lowest temperature limit at each sensor.
Use these fields to configure the highest voltage limit at each sensor.
Use these fields to configure the lowest voltage limit at each sensor.
The text box displays how often (in seconds) this screen refreshes. You
may change the refresh interval by typing a new number in the text box
and then clicking Set Interval.
Click Stop to halt statistic polling.