Supported Mibs; Rfc-1215 Snmp Traps - ZyXEL Communications Multi-service Access Platform MSAP2000 User Manual

Adsl access module 12-port adsl2+ multiplexer network module
Table of Contents

Advertisement

MSAP2000 AAMS User's Guide
SNMP itself is a simple request/response protocol based on the
manager/agent model. The manager issues a request and the agent returns
responses using the following protocol operations:
Table 43
COMMAND
Get
GetNext
Set
agent. Trap

18.3.1 Supported MIBs

MIBs let administrators collect statistics and monitor status and performance. The
MSAP2000 AAMS
supports the following MIBs:
MIB II IF MIB and ADSL line MIB (RFC-2662)
BRIDGE MIB: dot1dStp (RSTP), dot1dGarp (GARP)
SNMP MIB II (RFC-1215)
The MSAP2000 AAMS can also respond with specific data from the ZyXEL private
MIBs:
ZyXEL.mib
ZyXEL-AS-ATM.mib
ZyXEL-AESCommon.mib
ZyXEL-iesCommon.mib

18.3.2 RFC-1215 SNMP Traps

The MSAP2000 AAMS can send the following SNMP traps (defined in RFC-
1215) to an SNMP manager when an event occurs.
Table 44
TRAP
sendColdStartTrap
sendWarmStartTrap
sendLinkDownTrap
SNMP Commands
DESCRIPTION
Allows the manager to retrieve an object variable from the agent.
Allows the manager to retrieve the next object variable from a table or list within an
agent. In SNMPv1, when a manager wants to retrieve all elements of a table from
an agent, it initiates a Get operation, followed by a series of GetNext operations.
Allows the manager to set values for object variables within an
Used by the agent to inform the manager of some events.
RFC-1215 SNMP Traps
GENERIC SPECIFIC DESCRIPTION
TRAP
TRAP
0
0
1
0
2
0
This trap is sent when the AAMS is turned on.
This trap is sent when restart the AAMS using the web
configurator or the command line interface. The trap
will not be sent when you turn the power off and on.
This trap is sent when the Ethernet link is down.
117