MSAP2000 AAMS User's Guide
This chapter covers potential problems and possible remedies. After each
problem description, some steps are provided to help you to diagnose and solve
the problem.

32.1 The SYS or PWR LED Does Not Turn On

Table 68
STEPS
1
2
3

32.2 The ALM LED Is On

The ALM (alarm) LED lights when the MSAP2000 AAMS is overheated or the
voltage readings are outside the tolerance levels.
Table 69
STEPS
1
2
3
SYS LED Troubleshooting
CORRECTIVE ACTION
Make sure the power wires are properly connected to the power supply and the power
supply is operating normally. Make sure you are using the correct power source (refer to
the appendices).
Make sure the power wires are connected properly.
The LED itself or the unit may be faulty; contact your vendor.
ALM LED Troubleshooting
CORRECTIVE ACTION
Use the statistics monitor command to verify the cause of the alarm. See step 2 if the unit
is overheated, and step 3 if the voltages are out of the allowed ranges.
Ensure that the MSAP2000 AAMS is installed in a well-ventilated area and that normal
operation of the fans is not inhibited. Keep the bottom, top and all sides clear of
obstructions and away from the exhaust of other equipment.
If the voltage levels are outside the allowed range, take a screen shot of the
statistics monitor command display and contact your vendor.