8.2

Counter Format Selection

Set the counter format in the CC IE Field configuration.
1.
Set "Parameter write" for "Method selection".
"CC IE Field Configuration" window
2.
Set "CH Counter format".
8.2.1

Linear counter function

(1) Operation of the linear counter
• When the linear counter is selected, pulses are counted between -2147483648 (lower limit value) and
2147483647 (upper limit value).
• The preset/replace function and the comparison output function can be used together.
• The following figure shows the relationship between CH Present value (RWr10 to RWr11, RWr28 to
RWr29) of the counter and remote registers at overflow and underflow for the linear counter function.
Controlled by the high-speed counter module
Controlled by the program
CH
(RWr10 to RWr11,
RWr28 to RWr29)
CH
Underflow detection flag
(RWr20.b1, RWr38.b1)
CH
Overflow detection flag
(RWr20.b2, RWr38.b2)
CH
Preset/replace command
[CC IE Field Configuration]
+2147483647
0
Present value
-2147483648
OFF (0)
OFF (0)
(RY21, RY39)
OFF
Select a high-speed counter module in "List of stations"
[Parameter Processing of Slave Station]
1)
Underflow
ON (1)
ON
2)
*1
T
or more
1
CHAPTER 8 FUNCTIONS
3)
Overflow
ON (1)
4)
*1
T
or more
1
8
95