Mitsubishi NZ2GFCF-D62PD2 User Manual page 255

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Remote
output
Signal name
(RY) No.
Update flag
reset command
(Measured
CH1
frequency
RY2C
value)
Update flag
reset command
(Measured
rotation speed
RY44
CH2
value)
Pulse
RY30
CH1
measurement
start command
(Function input
RY48
CH2
terminal)
Measured pulse
RY31
CH1
value update
flag reset
command
(Function input
RY49
CH2
terminal)
Pulse
RY32
CH1
measurement
start command
(Latch counter
RY4A
CH2
input terminal)
Measured pulse
RY33
CH1
value update
flag reset
command
(Latch counter
RY4B
CH2
input terminal)
RY35
CH1
ON width setting
change request
(PWM output)
RY4D
CH2
RY36
CH1
Error reset
command
RY4E
CH2
Operation
timing
• Turn on this signal to reset CH Update flag (Measured frequency value) (RX2D,
RX45).
• When this signal is turned on, CH Update flag (Measured frequency value)
(RX2D, RX45) turns off. After resetting is completed, CH Update flag reset
completed (Measured frequency value) (RX2C, RX44) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
• Turn on this signal to reset CH Update flag (Measured rotation speed value)
(RX2D, RX45).
• When this signal is turned on, CH Update flag (Measured rotation speed value)
(RX2D, RX45) turns off. After resetting is completed, CH Update flag reset
completed (Measured rotation speed value) (RX2C, RX44) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
• Turn on this signal to start measuring pulses using CH Function input terminal
(FUNC1, FUNC2).
• When this signal is turned on, the measurement of pulses using CH Function
input terminal (FUNC1, FUNC2) starts. When the measurement starts, Operating
(1) is set in CH Pulse measurement flag (Function input terminal) (RWr20.b6,
RWr38.b6).
• Turn on this signal to reset CH Measured pulse value update flag (Function
input terminal) (RX32, RX4A).
• When this signal is turned on, CH Measured pulse value update flag (Function
input terminal) (RX32, RX4A) turns off. After resetting is completed, CH
Measured pulse value update flag reset completed (Function input terminal)
(RX31, RX49) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
• Turn on this signal to start measuring pulses using CH Latch counter input
terminal (LATCH1, LATCH2).
• When this signal is turned on, the measurement of pulses using CH Latch
counter input terminal (LATCH1, LATCH2) starts. When the measurement starts,
Operating (1) is set in CH Pulse measurement flag (Latch counter input
terminal) (RWr20.b7, RWr38.b7).
• Turn on this signal to reset CH Measured pulse value update flag (Latch counter
input terminal) (RX34, RX4C).
• When this signal is turned on, CH Measured pulse value update flag (Latch
counter input terminal) (RX34, RX4C) turns off. After resetting is completed, CH
Measured pulse value update flag reset completed (Latch counter input terminal)
(RX33, RX4B) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
• Turn on this signal to activate the changes of CH ON width setting (PWM output)
(RWw1E to RWw1F, RWw36 to RWw37) during PWM output.
• When this signal is turned on, CH ON width setting (PWM output) (RWw1E to
RWw1F, RWw36 to RWw37) is reflected to the high-speed counter module. After
the setting values are reflected, CH ON width setting change completed (PWM
output) (RX35, RX4D) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
• Turn on this signal to reset CH Latest error code (RWr22, RWr3A) and CH
Latest warning code (RWr23, RWr3B).
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
Description
APPENDICES
A
253

Advertisement

Table of Contents
loading