Mitsubishi NZ2GFCF-D62PD2 User Manual page 249

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Remote input
Signal name
(RX) No.
RX33
CH1
Measured pulse
value update
flag reset
completed
(Latch counter
input terminal)
RX4B
CH2
RX34
CH1
Measured pulse
value update
flag (Latch
counter input
terminal)
RX4C
CH2
RX35
CH1
ON width setting
change
completed
(PWM output)
RX4D
CH2
• This signal turns on when resetting CH Measured pulse value update flag (Latch counter
input terminal) (RX34, RX4C) by CH Measured pulse value update flag reset command
(Latch counter input terminal) (RY33, RY4B) is completed.
• This signal turns off when CH Measured pulse value update flag reset command (Latch
counter input terminal) (RY33, RY4B) is turned off.
Controlled by the high-speed counter module
Controlled by the program
CH
Measured pulse value
update flag reset command
(Latch counter input terminal) (RY33, RY4B)
CH
Measured pulse value update flag
(Latch counter input terminal)
CH
Measured pulse value
update flag reset completed
(Latch counter input terminal) (RX33, RX4B)
• This signal turns on when CH Measured pulse value (Latch counter input terminal)
(RWr1E to RWr1F, RWr36 to RWr37) is updated.
• CH Measured pulse value (Latch counter input terminal) (RWr1E to RWr1F, RWr36 to
RWr37) is updated without resetting this flag.
• This signal turns off when CH Measured pulse value update flag reset command (Latch
counter input terminal) (RY33, RY4B) is turned on.
*1
• Up to ΔT
delay occurs until this signal turns on after CH Measured pulse value (Latch
1
counter input terminal) (RWr1E to RWr1F, RWr36 to RWr37) is updated.
(For the overview of the operation, refer to the description of CH Measured pulse value
update flag reset completed (Latch counter input terminal) (RX33, RX4B).)
*1
For ΔT
, refer to Page 283, Appendix 4.
1
• This signal turns on when the changes of CH ON width setting (PWM output) (RWw1E to
RWw1F, RWw36 to RWw37) are reflected to the high-speed counter module by CH ON
width setting change request (PWM output) (RY35, RY4D).
• This signal turns off when CH ON width setting change request (PWM output) (RY35,
RY4D) is turned off.
Controlled by the high-speed counter module
Controlled by the program
CH
ON width setting change request
(PWM output)
CH
ON width setting
(PWM output)
(RWw1E to RWw1F, RWw36 to RWw37)
CH
ON width setting change completed
(PWM output)
Description
ON
OFF
ON
OFF
(RX34, RX4C)
ON
OFF
ON
OFF
(RY35, RY4D)
100
OFF
(RX35, RX4D)
APPENDICES
200
ON
247
A