For the REMFR and REMTO instructions, refer to the following.
User's manual for the master/local module used
*2
For the access method, refer to the following.
• Parameter area (
• Error history area (
Do not access the system area using the REMFR or REMTO instruction. Doing so may cause the module to malfunction.
(1) Parameter area (address: 0000
For the parameter area, parameters can be set using the CC IE Field configuration of GX Works2 or using the
REMTO instruction.
The parameter in the parameter area is backed up to the nonvolatile memory.
The parameter backed up to the nonvolatile memory is read to the parameter area when the module power
supply is turned off then on or the module returns from remote reset.
If the parameter is written from the parameter setting of the CC IE Field configuration of GX Works2, it is also
written to the nonvolatile memory at that time. When the parameter is written using the REMTO instruction, it is
written to the nonvolatile memory when Initial data setting request flag (RY9) is turned off then on. At this time,
the parameter is written to the nonvolatile memory even though it is incorrect. When the power supply is turned
off then on with an incorrect parameter written, the incorrect parameter is read from the nonvolatile memory and
an error code is stored to CH Latest error code (RWr22, RWr3A). Take corrective action according to the error
code list. (
Type
Decimal
0
1
Station-based
2
parameter data
3
4 to 255
256
257
258
259
260
261
262 to 287
Module-based
parameter data
288
(main module)
289
290
291
292
293
294
295
42
Page 80, Section 7.1)
Page 205, Section 11.1)
Page 208, Section 11.2)
Address
Hexadecimal
0000
System area
H
0001
Input response time setting
H
0002
Output HOLD/CLEAR setting
H
0003
Cyclic data update watch time setting
H
0004
to 00FF
System area
H
H
0100
Comparison output setting
H
0101
Coincidence output channel assignment setting
H
0102
Coincidence output comparison condition setting
H
0103
Preset/replace setting at coincidence output
H
0104
Cam switch output unit assignment setting
H
0105
Cam switch output channel assignment setting
H
0106
to 011F
System area
H
H
0120
CH1 Operation mode setting
H
0121
CH1 Count source selection
H
0122
CH1 Pulse input mode
H
0123
CH1 Counting speed setting
H
0124
CH1 Counter format
H
0125
CH1 Phase Z setting
H
0126
CH1 Counter function selection
H
0127
CH1 Function input logic setting
H
to 04FF
)
H
H
Description
Read/
*1
Default
*2
Write
0005
R/W
H
0000
R/W
H
0
R/W
0
R/W
0000
R/W
H
0000
R/W
H
0000
R/W
H
0
R/W
0000
R/W
H
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0000
R/W
H
0
R/W
0
R/W