Mitsubishi NZ2GFCF-D62PD2 User Manual page 95

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Pulse input
mode
For counting up
2-phase multiple of 1
For counting
down
For counting up
2-phase multiple of 2
For counting
down
For counting up
2-phase multiple of 4
For counting
down
When using the phase B pulse input or CH Count down command (RY22, RY3A) for 1-phase pulse input, turn off the
unused signals.
When the phase B pulse input or CH Count down command (RY22, RY3A) is on, countdown is performed with the phase
A pulse input.
(a) 1-phase pulse input
For 1-phase pulse input, multiple of 1 or multiple of 2 can be selected as a counting method.
The following figure shows the relationship between phase A pulse input and phase B pulse input or CH
Count down command (RY22, RY3A).
Count timing
A
B
A
B
A
B
A
B
A
B
A
B
Pulse input
Encoder
B or CH
Count down command
(RY22, RY3A)
Counts on the rising edge (↑) of φA while φB is off.
Counts on the falling edge (↓) of φA while φB is off.
Counts on the rising edge (↑) of φA while φB is off.
Counts on the falling edge (↓) of φA while φB is on.
Counts on the rising edge (↑) of φA while φB is on.
Counts on the falling edge (↓) of φA while φB is off.
Counts on the rising edge (↑) of φA while φB is off.
Counts on the falling edge (↓) of φA while φB is on.
Counts on the rising edge (↑) of φB while φA is on.
Counts on the falling edge (↓) of φB while φA is off.
Counts on the rising edge (↑) of φA while φB is on.
Counts on the falling edge (↓) of φA while φB is off.
Counts on the rising edge (↑) of φB while φA is off.
Counts on the falling edge (↓) of φB while φA is on.
High-speed counter module
A
B
CHAPTER 8 FUNCTIONS
93
8