Counter Function Selection - Mitsubishi NZ2GFCF-D62PD2 User Manual

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

8.6

Counter Function Selection

When CH Selected counter function start command (RY25, RY3D) or CH Function input terminal (FUNC1,
FUNC2) is input, one of the functions shown below can be used.
The function can be selected for each channel.
(1) Counter function selection list
Function name
Count disable function
Latch counter function
Sampling counter function
Periodic pulse counter function
Count disable/preset/replace
function
Latch counter/preset/replace
function
(2) Setting method of the counter function selection
1.
Set "Parameter write" for "Method selection".
"CC IE Field Configuration" window
2.
For "CH Counter function selection", select a counter function to be used.
Remote buffer memory setting
CH
CH
Operation
Counter
mode
function
setting
selection
(address:
(address:
0120
,
0126
,
H
H
0140
)
0146
)
H
H
0
0
0
1
0
2
0
3
0
4
0
5
[CC IE Field Configuration]
CH Function
CH
input response
Function
time setting
input logic
(address:
setting
0129
.b2 to b3,
(address:
H
0127
, 0147
)
0149
.b2 to b3)
H
H
H
0/1
00/01/10
0/1
00/01/10
0/1
00/01/10
0/1
00/01/10
0/1
00/01/10
0/1
00/01/10
Select a high-speed counter module in "List of stations"
[Parameter Processing of Slave Station]
CHAPTER 8 FUNCTIONS
: Enable ⎯: Disable
Method
CH Selected
CH Function
counter function
input terminal
start command
(FUNC1,
(RY25, RY3D)
FUNC2)
129
8