Setting item
Z phase input response time setting
Function input response time setting
Latch counter input response time setting
Pulse measurement setting (Function
input terminal)
Pulse measurement setting (Latch
counter input terminal)
6.
Click the
● When using the extension module, also set the parameter of the extension module.
For the parameter of the extension module, refer to the following.
Manual for the extension module used
● Set all the items for the parameter. If any blank exists, the parameter cannot be written to the high-speed counter module.
● To read the parameter from the high-speed counter module, set "Parameter read" for "Method selection" and click the
● When the following message is displayed, take corrective action for the error code in <>. (
● When the parameters are written, the contents in the extended parameter area are stored in the nonvolatile memory.
● When writing the parameters while Initial data processing request flag (RX8) is off, set values in the remote registers
(RWw) beforehand. The values in the remote registers (RWw) related to the setting values of the parameters are
checked at the writing. If the setting is incorrect, an error occurs.
OFF → ON Response
Setting
time
0
0.25µs
1
0.1ms
2
1.0ms
OFF → ON Response
Setting
time
0
0.02ms
1
0.1ms
2
1.0ms
OFF → ON Response
Setting
time
0
0.02ms
1
0.1ms
2
1.0ms
0: Pulse ON Width
1: Pulse OFF Width
0: Pulse ON Width
1: Pulse OFF Width
button to write the parameter to the high-speed counter module.
button.
Setting details
ON → OFF Response
time
2.5µs
0.1ms
1.0ms
ON → OFF Response
time
0.1ms
0.1ms
1.0ms
ON → OFF Response
time
0.1ms
0.1ms
1.0ms
CHAPTER 7 VARIOUS SETTINGS
Reference
Page 273, Appendix 3 (10)
Page 273, Appendix 3 (10)
Page 273, Appendix 3 (10)
Page 156, Section 8.15
Page 156, Section 8.15
Page 208, Section 11.2)
85