Mitsubishi NZ2GFCF-D62PD2 User Manual page 134

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

No.
1)
Counting starts by turning on CH Count enable command (RY24, RY3C).
Counting stops by turning on CH Selected counter function start command (RY25, RY3D).
2)
Also, CH Counter function detection (RX25, RX3D) turns on by turning on CH Selected counter function start command (RY25,
RY3D).
Counting resumes by turning off CH Selected counter function start command (RY25, RY3D).
3)
Also, CH Counter function detection (RX25, RX3D) turns off by turning off CH Selected counter function start command (RY25,
RY3D).
4)
Counting stops by turning on CH Function input terminal (FUNC1, FUNC2).
5)
Counting resumes by turning off CH Function input terminal (FUNC1, FUNC2).
6)
Counting stops by turning off CH Count enable command (RY24, RY3C).
Counting stops regardless of CH Selected counter function start command (RY25, RY3D) since CH Count enable command
7)
(RY24, RY3C) is off.
Counting remains stopped even if CH Count enable command (RY24, RY3C) is turned on since CH Selected counter function
8)
start command (RY25, RY3D) is on.
9)
Counting resumes by turning off CH Selected counter function start command (RY25, RY3D).