Term - Mitsubishi NZ2GFCF-D62PD2 User Manual

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Unless otherwise specified, this manual uses the following terms.

Term

CC-Link IE Field Network
GX Works2
REMFR
REMTO
Intelligent device station
Cyclic transmission
Slave station
Data link
Transient transmission
Network module
Buffer memory
Programming tool
Master/local module
Master station
Remote I/O station
Remote device station
Remote buffer memory
Remote register (RWr)
Remote register (RWw)
Remote output (RY)
Remote input (RX)
Link device
12
TERM
A high-speed and large-capacity open field network that is based on Ethernet (1000BASE-T)
The product name of the software package for the MELSEC programmable controllers
The abbreviation for ZP.REMFR.
This dedicated instruction is used in programs of the master/local module.
The abbreviation for ZP.REMTO.
This dedicated instruction is used in programs of the master/local module.
A station that deals with bit data and word data.
The station can communicate with the master station and other local stations. The station cannot
communicate with other remote I/O stations, remote device stations and intelligent device stations.
The station can perform the cyclic transmission and transient transmission.
A function by which data are periodically exchanged among stations on the same network using link
devices (RX, RY, RWw, and RWr)
A generic term for stations other than a master station: local station, remote I/O station, remote
device station, and intelligent device station
A generic term for cyclic transmission and transient transmission
A function of communication with another station, which is used when requested by a dedicated
instruction or GX Works2
A generic term for the following modules:
• CC-Link IE Field Network module
• CC-Link IE Controller Network module
• Ethernet interface module
• MELSECNET/H module
• MELSECNET/10 module
A memory in an intelligent function module, where data (such as setting values and monitoring
values) are stored
Another term for GX Works2
A generic term for the CC-Link IE Field Network master/local module
A station that controls CC-Link IE Field Network. The station can communicate with all stations.
Only one master station can be used in a network.
The station can perform the cyclic transmission and transient transmission.
A station that deals with bit data.
The station can communicate with the master station and other local stations. The station cannot
communicate with other remote I/O stations, remote device stations and intelligent device stations.
The station can perform the cyclic transmission.
A station that deals with bit data and word data.
The station can communicate with the master station and other local stations. The station cannot
communicate with other remote I/O stations, remote device stations and intelligent device stations.
The station can perform the cyclic transmission.
Buffer memory in a remote device station
Word data input from a slave station to the master station (For some areas in a local station, data are
output in the opposite direction.)
User's manual for the master/local module used
Word data output from the master station to a slave station (For some areas in a local station, data
are output in the opposite direction.)
User's manual for the master/local module used
Bit data output from the master station to a slave station (For some areas in a local station, data are
output in the opposite direction.)
User's manual for the master/local module used
Bit data input from a slave station to the master station (For some areas in a local station, data are
output in the opposite direction.)
User's manual for the master/local module used
A device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
Description

Advertisement

Table of Contents
loading

Table of Contents