8.3

Comparison Output Function

The comparison output function outputs ON/OFF signals comparing the count value with any point or range set by the
user.
The coincidence output function or the cam switch function can be selected depending on the processing method.
Set the comparison output function in the parameter setting window or Comparison output setting (address: 0100
8.3.1
Operation overview of the coincidence output function and
the cam switch function
The following table shows the operation overview of the coincidence output function and the cam switch function.
Item
Comparison target
Number of output points per
channel
Comparison start timing
Setting item for comparison
point/range
Change method of comparison
point/range
Internal
output
Comparison result
External
output
Preset/replace (at coincidence
output) function
Output reset timing
External output enable timing
*1
When Initial data processing request flag (RX8) is on, the setting data is not checked.
102
Coincidence output function
CH Present value (RWr10 to RWr11, RWr28 to
RWr29)
0 to 4 points
When Initial data processing request flag (RX8) is
off and Initial data setting completion flag (RX9) is
off
• Point setting (Coincidence output 1 to 4)/Lower
limit value setting (Coincidence output 1 to 4)
(RWw0 to RWw1, RWw4 to RWw5, RWw8 to
RWw9, RWwC to RWwD)
• Upper limit value setting (Coincidence output 1
to 4) (RWw2 to RWw3, RWw6 to RWw7,
RWwA to RWwB, RWwE to RWwF)
• Turning off then on Setting change request
(Coincidence output 1 to 4) (RY14 to RY17)
• Turning off then on Initial data processing
completion flag (RY8)
• Turning off then on Initial data setting request
*1
flag (RY9)
• Coincidence output 1 to 4 (RX10 to RX13)
• Counter value greater/smaller signal (RWr0)
(only for coincidence output)
Coincidence output 1 to 4 terminals (EQU1 to
EQU4)
Provided
• When Reset command (Coincidence output 1
to 4) (RY10 to RY13) is turned off then on (for
coincidence output)
• When values are counted outside the detection
area (for within-range output or out-of-range
output)
When CH Coincidence output enable
command (RY20, RY38) is turned off then on
Cam switch function
CH Present value (RWr10 to RWr11, RWr28 to
RWr29)
0 to 16 points
When CH Cam switch execute (RX26, RX3E) is
turned off then on
• Cam switch function parameter data (address:
1500
to 1FFF
)
H
H
Turning off then on CH Cam switch execute
(RX26, RX3E)
Cam switch output signal (RWr2)
Output terminals of the extension output module
Not provided
Automatically reset depending on Cam switch
function, step No.1 to No.16 setting (Output 1 to 16)
of remote buffer memory
When CH Cam switch execute (RX26, RX3E) is
turned off then on after CH Cam switch execute
command (RY26, RY3E) is turned off then on
).
H