(14)Remote registers (RWw1D to RWw21, RWw35 to RWw39)
Address
(RWw)
Item
CH1 CH2
PWM output
1D
35
assignment setting
1E
36
ON width setting
1F
37
(PWM output)
20
38
Cycle setting (PWM
21
39
output)
266
• Select an output target from Coincidence output 1 to 4 to output the PWM
waveform using the PWM output function.
• This setting applies only to coincidence outputs where the corresponding
channels are assigned using Coincidence output channel assignment setting
(address: 0101
). Two or more points can be set.
H
• The following shows the setting range.
b15
b14
b13
b12
b11
b10
0
0
0
0
0
0
0 (fixed)
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
• Set the ON width of the PWM waveform for the PWM output function.
• The following shows the setting range.
0, and 10 to 10000000 (increments of 0.1µs) (Set a value that is equal to or
smaller than the value in the cycle setting (PWM output).)
• The reflection timing of the setting value
1)
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
2)
When CH ON width setting change request (PWM output) (RY35, RY4D)
is turned off then on
• Set the cycle of the PWM waveform for the PWM output function.
• The following shows the setting range.
50 to 10000000 (increments of 0.1µs)
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
Description
b9
b8
b7
b6
b5
b4
b3
Coinci-
0
0
0
0
0
0
dence
output 4
Default
b2
b1
b0
0000
H
Coinci-
Coinci-
Coinci-
dence
dence
dence
output 3
output 2
output 1
0: No Assignment
1: Assignment
0
0

Advertisement