Mitsubishi NZ2GFCF-D62PD2 User Manual page 273

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

(8) Module-based parameter data (address: 0124
Address
Name
CH1
CH2
0124
0144
Counter format
H
H
0125
0145
Phase Z setting
H
H
• Set the counter format.
• The following shows the setting range.
0: Linear Counter
1: Ring Counter
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
• Set the trigger condition to replace a count value with the preset value by
CH Phase Z input terminal (Z1, Z2).
• Set whether to turn on CH External preset/replace (Z Phase) request
detection (RX23, RX3B) or not when a count value is replaced with the
preset value by CH Phase Z input terminal (Z1, Z2).
• While CH Z phase (Preset) trigger setting (address: 0125
0145
.b0 to b1) is on, CH External preset/replace (Z Phase) request
H
detection setting (address: 0125
External preset/replace (Z Phase) request detection (RX23, RX3B) is
always off.
• The following shows the setting range.
b15
b14
b13
b12
b11
b10
b9
0
0
0
0
0
0
0
0 (fixed)
1)
Z phase (Preset) trigger setting
00: Rising
01: Falling
10: Rising + Falling
11: During ON
2)
External preset/replace (Z Phase) request detection setting
0: ON at detection
1: Not ON at detection
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
to 0125
, 0144
H
H
Description
.b0 to b1,
H
.b4, 0145
.b4) is disabled and CH
H
H
b8
b7
b6
b5
b4
b3
0
0
0
0
2)
0
0 (fixed)
APPENDICES
to 0145
)
H
H
Default
0
b2
b1
b0
0000
H
0
1)
271
A