Mitsubishi NZ2GFCF-D62PD2 User Manual page 248

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Remote input
Signal name
(RX) No.
Update flag
(Measured
frequency
RX2D
CH1
value)
Update flag
(Measured
rotation speed
RX45
CH2
value)
RX31
CH1
Measured pulse
value update
flag reset
completed
(Function input
terminal)
RX49
CH2
RX32
CH1
Measured pulse
value update
flag (Function
input terminal)
RX4A
CH2
246
• This signal turns on when CH Measured frequency value (RWr1A to RWr1B, RWr32 to
RWr33) is updated. (
Page 148, Section 8.13)
• CH Measured frequency value (RWr1A to RWr1B, RWr32 to RWr33) is updated without
resetting this flag.
• This signal turns off when CH Update flag reset command (Measured frequency value)
(RY2C, RY44) is turned on.
*1
• Up to ΔT
delay occurs until this signal turns on after CH Measured frequency value
1
(RWr1A to RWr1B, RWr32 to RWr33) is updated.
(For the overview of the operation, refer to the description of CH Update flag reset
completed (Measured frequency value) (RX2C, RX44).)
*1
For ΔT
, refer to Page 283, Appendix 4.
1
• This signal turns on when CH Measured rotation speed value (RWr1A to RWr1B, RWr32
to RWr33) is updated. (
• CH Measured rotation speed value (RWr1A to RWr1B, RWr32 to RWr33) is updated
without resetting this flag.
• This signal turns off when CH Update flag reset command (Measured rotation speed
value) (RY2C, RY44) is turned on.
*1
• Up to ΔT
delay occurs until this signal turns on after CH Measured rotation speed value
1
(RWr1A to RWr1B, RWr32 to RWr33) is updated.
(For the overview of the operation, refer to the description of CH Update flag reset
completed (Measured rotation speed value) (RX2C, RX44).)
For ΔT
*1
, refer to Page 283, Appendix 4.
1
• This signal turns on when resetting CH Measured pulse value update flag (Function input
terminal) (RX32, RX4A) by CH Measured pulse value update flag reset command
(Function input terminal) (RY31, RY49) is completed.
• This signal turns off when CH Measured pulse value update flag reset command (Function
input terminal) (RY31, RY49) is turned off.
Controlled by the high-speed counter module
Controlled by the program
CH
Measured pulse value
update flag reset command
(Function input terminal) (RY31, RY49)
CH
Measured pulse value update flag
(Function input terminal) (RX32, RX4A)
CH
Measured pulse value
update flag reset completed
(Function input terminal) (RX31, RX49)
• This signal turns on when CH Measured pulse value (Function input terminal) (RWr1C to
RWr1D, RWr34 to RWr35) is updated.
• CH Measured pulse value (Function input terminal) (RWr1C to RWr1D, RWr34 to RWr35)
is updated without resetting this flag.
• This signal turns off when CH Measured pulse value update flag reset command (Function
input terminal) (RY31, RY49) is turned on.
*1
• Up to ΔT
delay occurs until this signal turns on after CH Measured pulse value
1
(Function input terminal) (RWr1C to RWr1D, RWr34 to RWr35) is updated.
(For the overview of the operation, refer to the description of CH Measured pulse value
update flag reset completed (Function input terminal) (RX31, RX49).)
For ΔT
*1
, refer to Page 283, Appendix 4.
1
Description
Page 152, Section 8.14)
ON
OFF
ON
OFF
OFF
ON

Advertisement

Table of Contents
loading

Table of Contents