Mitsubishi NZ2GFCF-D62PD2 User Manual page 159

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

(2) Terminals for the pulse measurement
The following table lists the terminals that are used for the pulse measurement for each channel.
Channel
CH1
CH2
(3) Pulse width to be measured
Set which pulse width (ON or OFF) is to be measured by using "CH Pulse measurement setting (Function input
terminal)" and "CH Pulse measurement setting (Latch counter input terminal)".
The measured value is stored in CH Measured pulse value (Function input terminal) (RWr1C to RWr1D, RWr34
to RWr35) or CH Measured pulse value (Latch counter input terminal) (RWr1E to RWr1F, RWr36 to RWr37).
Pulse width to be
measured
Pulse ON width
Pulse OFF width
(4) Measurable range of the pulses
The measurable range of the pulses is between 2000 and 2147483647 (0.2ms to approx. 214s). When the input
pulses are beyond the measurable range, the error code (660
(RWr22, RWr3A) and Error status flag (RXA) and the ERR. LED turns on.
To resume the measurement, input the pulses once again, or perform the operation as shown below.
Measurement to be resumed
Measurement with the function input
terminal
Measurement with the latch counter
input terminal
*1
The abbreviations mean as the follows.
• F start command: CH Pulse measurement start command (Function input terminal) (RY30, RY48)
• L start command: CH Pulse measurement start command (Latch counter input terminal) (RY32, RY4A)
• F measurement flag: CH Pulse measurement flag (Function input terminal) (RWr20.b6, RWr38.b6)
• L measurement flag: CH Pulse measurement flag (Latch counter input terminal) (RWr20.b7, RWr38.b7)
(5) Update timing of the measured values of pulses
The measured pulse value is updated in the remote register every ΔT
twice or more within ΔT
refer to the following.
• Internal Control Cycle and Response Delay Time (
Terminals for the pulse measurement
Function input terminal 1 (FUNC1)
Latch counter input terminal 1 (LATCH1)
Function input terminal 2 (FUNC2)
Latch counter input terminal 2 (LATCH2)
ON width
Setting value of pulse
width to be measured
0
1
Operation
Turn off then on the F start command.
Turn off then on the L start command.
, only the latest measured value is stored in the remote registers. For details on ΔT
2
OFF width
Description
The ON time of the input pulse is measured.
The OFF time of the input pulse is measured.
or 662
) is stored in CH Latest error code
H
H
The pulse measurement is not resumed until the F
*1
measurement flag or the L measurement flag changes
to Not operating (OFF) after the F start command or L
*1
start command is turned off.
cycle. So when the measurement is done
2
Page 283, Appendix 4)
CHAPTER 8 FUNCTIONS
Remarks
*1
,
2
157
8