Remote input
Signal name
(RX) No.
Setting change
RX14
completed
(Coincidence output 1)
Setting change
RX15
completed
(Coincidence output 2)
Setting change
RX16
completed
(Coincidence output 3)
Setting change
RX17
completed
(Coincidence output 4)
External power supply
RX1F
monitor state flag
240
• This signal turns on when the changes of the following remote registers (RWw) are reflected
to the high-speed counter module in the coincidence output function.
• Point setting (Coincidence output 1 to 4)/Lower limit value setting (Coincidence output 1 to
4) (RWw0 to RWw1, RWw4 to RWw5, RWw8 to RWw9, RWwC to RWwD)
• Upper limit value setting (Coincidence output 1 to 4) (RWw2 to RWw3, RWw6 to RWw7,
RWwA to RWwB, RWwE to RWwF)
• For Coincidence output 1, Setting change completed (Coincidence output 1) (RX14) turns
on after the changes of Point setting (Coincidence output 1)/Lower limit value setting
(Coincidence output 1) (RWw0 to RWw1) and Upper limit value setting (Coincidence output
1) (RWw2 to RWw3) are reflected to the high-speed counter module by Setting change
request (Coincidence output 1) (RY14).
• For Coincidence output 1, Setting change completed (Coincidence output 1) (RX14) turns
off when Setting change request (Coincidence output 1) (RY14) is turned off.
• For Coincidence output 2 to 4, each corresponding remote I/O signals and remote register
(RWw) are used.
Controlled by the high-speed counter module
Controlled by the program
Setting change request
(Coincidence output 1 to 4)
Point setting (Coincidence output 1 to 4)/
Lower limit value setting
(Coincidence output 1 to 4)
(RWw0 to RWw1, RWw4 to RWw5,
RWw8 to RWw9, RWwC to RWwD)
Upper limit value setting (Coincidence output 1 to 4)
(RWw2 to RWw3, RWw6 to RWw7,
RWwA to RWwB, RWwE to RWwF)
Setting change completed
(Coincidence output 1 to 4)
• This signal turns on when the external power supply monitoring function is enabled by
turning on External power supply monitor request flag (RY1F).
• This signal turns off when the external power supply monitoring function is disabled by
turning off External power supply monitor request flag (RY1F).
Controlled by the high-speed counter module
External power supply
monitor request flag
External power supply
monitoring function
External power supply
monitor state flag
Description
OFF
(RY14 to RY17)
0
0
OFF
(RX14 to RX17)
ON
OFF
(RY1F)
Disable
ON
OFF
(RX1F)
ON
1000
2000
ON
Enable
Disable