(2) List of I/O signal details
The following table lists the signals for the high-speed counter module connectors for external devices.
I/O
Symbol
classification
A1-24V
A1-5V
A1-DIF
A1-COM
B1-24V
B1-5V
B1-DIF
B1-COM
Z1-24V
Z1-5V
Z1-DIF
Z1-COM
A2-24V
A2-5V
A2-DIF
A2-COM
B2-24V
Input
B2-5V
B2-DIF
B2-COM
Z2-24V
Z2-5V
Z2-DIF
Z2-COM
FUNC1-24V
FUNC1-5V
FUNC2-24V
FUNC2-5V
LATCH1-24V
LATCH1-5V
LATCH2-24V
LATCH2-5V
CTRLCOM
EQU1
EQU2
EQU3
Output
EQU4
EQUCOM
72
Pin
Signal name
number
B20
CH1 Phase A pulse input 24V (+)
A20
CH1 Phase A pulse input 5V (+)
B19
CH1 Phase A pulse differential input (+)
A19
CH1 Phase A pulse input common (-)
B18
CH1 Phase B pulse input 24V (+)
A18
CH1 Phase B pulse input 5V (+)
B17
CH1 Phase B pulse differential input (+)
A17
CH1 Phase B pulse input common (-)
B16
CH1 Phase Z input 24V (+)
A16
CH1 Phase Z input 5V (+)
B15
CH1 Phase Z differential input (+)
A15
CH1 Phase Z input common (-)
B14
CH2 Phase A pulse input 24V (+)
A14
CH2 Phase A pulse input 5V (+)
B13
CH2 Phase A pulse differential input (+)
A13
CH2 Phase A pulse input common (-)
B12
CH2 Phase B pulse input 24V (+)
A12
CH2 Phase B pulse input 5V (+)
B11
CH2 Phase B pulse differential input (+)
A11
CH2 Phase B pulse input common (-)
B10
CH2 Phase Z input 24V (+)
A10
CH2 Phase Z input 5V (+)
B09
CH2 Phase Z differential input (+)
A09
CH2 Phase Z input common (-)
B08
CH1 Function input 24V
B07
CH1 Function input 5V
B05
CH2 Function input 24V
B04
CH2 Function input 5V
A08
CH1 Latch counter input 24V
A07
CH1 Latch counter input 5V
A05
CH2 Latch counter input 24V
A04
CH2 Latch counter input 5V
A06, B06
Control input common
B03
Coincidence output 1 (+)
A03
Coincidence output 2 (+)
B01
Coincidence output 3 (+)
A01
Coincidence output 4 (+)
A02, B02
Coincidence output common (-)
Description
• This signal inputs + (plus) side of phase A pulse.
• This signal inputs - (minus) side of phase A pulse.
• This signal inputs + (plus) side of phase B pulse.
• This signal inputs - (minus) side of phase B pulse.
• This signal inputs + (plus) side of phase Z.
• Turn on this signal to replace a count value by the external signal.
• The count value is replaced with the preset value when this signal
becomes on (when "CH1 Z phase (Preset) trigger setting" is set
to "0: Rising").
• This signal inputs - (minus) side of phase Z.
• This signal inputs + (plus) side of phase A pulse.
• This signal inputs - (minus) side of phase A pulse.
• This signal inputs + (plus) side of phase B pulse.
• This signal inputs - (minus) side of phase B pulse.
• This signal inputs + (plus) side of phase Z.
• Turn on this signal to replace a count value by the external signal.
• The count value is replaced with the preset value when this signal
becomes on (when "CH2 Z phase (Preset) trigger setting" is set
to "0: Rising").
• This signal inputs - (minus) side of phase Z.
• Turn on this signal to execute the selected counter function start
command by the external signal.
• Turn on this signal to latch a count value by the external signal.
• The count value is latched and stored in remote registers when
this signal becomes on.
• Common for function input
• Common for latch counter input
• It is common between channels.
• With the coincidence output function activated, the high-speed
counter module outputs a signal when the count value is matched
with the preset comparison condition.
• When the PWM output function is used, the high-speed counter
module outputs the PWM waveform.
• It inputs 0V when Coincidence output 1 to 4 are used.
• Common for coincidence outputs
• It is common between channels.