Mitsubishi NZ2GFCF-D62PD2 User Manual page 282

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

(20)Station-based control data (address: 1005
Address
Name
Module operation
information
1005
H
initialization
completed
(21)Extended parameter data (address: 1500
Address
Name
Cam switch function,
1500
H
step type (Output 1)
Cam switch function,
1501
number of steps
H
(Output 1)
Cam switch function,
1502
H
step No.1 setting
1503
H
(Output 1)
Cam switch function,
1520
H
step No.16 setting
1521
H
(Output 1)
280
• When initialization of the module operation information stored in the remote
buffer memory and the nonvolatile memory is completed, Module operation
information initialization completed (address: 1005
is completed (1).
• When Module operation information initialization command (address: 1004
is set to Not commanded (0), Module operation information initialization
completed (address: 1005
H
• The following shows the range of values which can be stored.
b15
b14
b13
b12
b11
b10
b9
0
0
0
0
0
0
0
0 (fixed)
Set the step type for the cam of Output 1.
• Setting range
0: Starts with output status being OFF
1: Starts with output status being ON
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
Set the number of steps for the cam of Output 1.
• Setting range
0 to 16
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
Set the count value for switching ON and OFF of the output at the step No.1 of
Output 1.
• Setting range
-2147483648 to 2147483647
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
Set the count value for switching ON and OFF of the output at the step No.16 of
Output 1.
• Setting range
-2147483648to 2147483647
• The reflection timing of the setting value
When CH Cam switch execute command/PWM output start command
(RY26, RY3E) is turned off then on
)
H
Description
) changes to Initialization
H
) changes to Initialization is not performed (0).
b8
b7
b6
b5
b4
b3
b2
b1
0
0
0
0
0
0
0
0
to 1521
)
H
H
Description
Default
)
H
0000
H
b0
0: Initialization is
not performed
1: Initialization is
completed
Default
0
0
0
0