Mitsubishi NZ2GFCF-D62PD2 User Manual page 93

Cc-link ie field network high-speed counter module
Table of Contents

Advertisement

Setting
Operation mode
value
setting
*1
Frequency
measurem
1
ent mode
Rotation
speed
2
measurem
ent mode
Dedicated
mode
Pulse
measurem
3
ent mode
PWM
output
4
mode
Common
*1
The value set in CH Operation mode setting (address: 0120
*2
The value set in Comparison output setting (address: 0100
*3
The value set in CH Counter function selection (address: 0126
Function name
In this mode, the pulses of the pulse input terminals
in phase A and B are counted and the frequency is
automatically calculated.
Frequency measurement function
In this mode, the pulses of the pulse input terminals
in phase A and B are counted and the rotation
speed is automatically calculated.
Rotation speed measurement function
In this mode, the ON width or OFF width of pulses
input to the function input terminal or latch counter
input terminal is measured.
Pulse measurement function
In this mode, the PWM waveform of 200kHz at a
maximum is output from any coincidence output 1
to 4 terminals (EQU1 to EQU4).
PWM output function
Error notification function
Output HOLD/CLEAR setting function
Cyclic data update watch function
Function at the extension I/O module installation
Input function (extension input module)
Output function (extension output module)
Input response time setting function (extension
input module)
External power supply monitoring function
(extension output module)
Number of ON times integration function
(extension output module)
CHAPTER 7 VARIOUS SETTINGS
Comparison
output setting
*2
Coinci-
Cam
dence
, 0140
)
H
H
)
H
, 0146
)
H
H
Counter
function
Reference
selection
*3
Page 148,
Section 8.13
Page 152,
Section 8.14
Page 156,
Section 8.15
Page 160,
Section 8.16
Page 169,
Section 8.19
Page 167,
Section 8.17
Page 168,
Section 8.18
Page 172,
Section 8.20
91
7