4.4

Output Holding Function Cancellation Setting

This setting can select the setting to hold the analog data output or to output the offset data (0V for voltage
output mode, 4mA for current output mode) at stoppage of the PLC.
To cancel or set the output holding function, use the following special auxiliary relays:
Special auxiliary relay
1st
2nd
M8264
M8274
M8265
M8275
M8266
M8276
M8267
M8277
1. Example of program
To set or cancel the output holding function for a channel, create a sequence program as follows:
1) To set the output holding function for
channel 1 of the 1st analog special adapter:
M8001
Normally OFF
4.5

Output Setting Data

4DA-ADP performs D/A conversion on the output setting data (digital data) into analog data, and outputs the
analog data.
Use the special data registers shown in the following table for the output setting data:
Special data register
1st
2nd
D8260
D8270
D8261
D8271
D8262
D8272
D8263
D8273
1. Example of program
M8000
Normally ON
Using the indicator or the sequence program, input the digital data to be subject to D/A conversion (to be
output as analog data) in D100 and D101.
3rd
4th
Output holding function cancellation
M8284
M8294
setting for channel 1
Output holding function cancellation
M8285
M8295
setting for channel 2
Output holding function cancellation
M8286
M8296
setting for channel 3
Output holding function cancellation
M8287
M8297
setting for channel 4
2) To cancel the output holding function for
M8264
3rd
4th
D8280
D8290
Channel-1 output setting data
D8281
D8291
Channel-2 output setting data
D8282
D8292
Channel-3 output setting data
D8283
D8293
Channel-4 output setting data
FNC 12
D100
D8260
MOV
FNC 12
D101
D8261
MOV
4.4 Output Holding Function Cancellation Setting
Description
OFF: Holds the analog data output
ON : Outputs the offset data at
channel 2 of the 1st analog special adapter:
M8000
Normally ON
Numeric data type: Decimal (K)
Description
Performs D/A conversion using the digital
data stored in the D100 for channel 1 of
the 1st analog special adapter.
Performs D/A conversion using the digital
data stored in the D101 for channel 2 of
the 1st analog special adapter.
4 Programming
just before stop of the PLC.
stop of the PLC.
M8265
D-17
A
B
C
D
E
F
G