Valid format is xx:xx:xx:xx:xx:xx.
Use Source MAC Mask to specify the Source MAC address mask specifying which bits in
19.
the Source MAC to compare against an Ethernet frame.
Valid format is xx:xx:xx:xx:xx:xx.
Use VLAN to specify the VLAN ID to compare against an Ethernet frame.
20.
Valid range of values is 1 to 4095. Either VLAN range or VLAN can be configured.
Use Logging to enable or disable logging.
21.
When set to Enable, logging is enabled for this ACL rule (subject to resource availability
in the device). If the access list trap flag is also enabled, this causes periodic traps to be
generated indicating the number of times this rule was hit during the current report
interval. A fixed 5 minute report interval is used for the entire system. A trap is not issued
if the ACL rule hit count is zero for the current interval. This field is only supported for a
Deny action.
Use Rate Limit Conform Data Rate to specify the value of the conforming data rate of
22.
MAC ACL rule.
Valid values are 1 to 4294967295 in Kbps.
Use Rate Limit Burst Size to specify the burst size of MAC ACL rule.
23.
Valid values are 1 to 128 in Kbytes.
Use Time Range to enter the name of the time range associated with the MAC ACL rule.
24.
The Rule Status displays if the ACL rule is active or inactive. If this field is blank, no timer
schedules are assigned to the rule.
Click the Apply button.
25.
Your settings are saved.

Configure MAC Binding

When an ACL is bound to an interface, all the rules that are defined are applied to the
selected interface. Use the MAC Binding Configuration page to assign MAC ACL lists to ACL
priorities and interfaces.
To configure MAC binding:
Launch a web browser.
1.
In the address field of your web browser, enter the IP address of the switch.
2.
The login window opens.
Enter the user name and password.
3.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
Click the Login button.
4.
Manage Device Security