Select the BPDU Filter Disable or Enable radio button.
12.
This specifies whether the BPDU Filter feature is enabled. STP BPDU filtering applies to
all operational edge ports. Edge Port in an operational state is supposed to be connected
to hosts that typically drop BPDUs. If an operational edge port receives a BPDU, it
immediately loses its operational status. In that case, if BPDU filtering is enabled on this
port then it drops the BPDUs received on this port.
Select the Fast Backbone Mode Disable or Enable radio button. (PVSTP only.)
13.
Use this option to choose a new indirect link when an indirect link fails. The system does
not ignore inferior BPDUs, as is done in 802.1d. Rather the system uses the BPDUs to
age out on the port it received the BPDUs. Later the system sends out root link queries on
other non-designated ports. Based on the replies, if there is a positive response to at
least one of them, it chooses a new indirect link. Fast Backbone mode is disabled by
default.
Select the Fast Uplink Mode Disable or Enable radio button. (PVSTP only.)
14.
This option reduces the recovery time in selecting a new root port when the primary root
port goes down. Fast Uplink mode is disabled by default.
Use the Max Update Rate field to configure the Fast Uplink Maximum Update Rate.
15.
This field is enabled for configuration when Fast Uplink mode is enabled. Allowed values
are 0 to 32000 packets per second. The default value is 150.
Click the Apply button.
16.
Your settings are saved.
The following table describes the nonconfigurable information displayed on the page.
Table 74. STP Configuration
Field
Configuration Digest Key
Configuration Format Selector
STP Status
MST ID
VID ID
FID ID
Description
The 16-byte signature of type HMAC-MD5 created from the MST
Configuration Table (a VLAN ID-to-MST ID mapping) which is used to
identify the configuration currently being used.
The version of the configuration format being used in the exchange of
BPDUs.
Table consisting of the MST instances (including the CST) and the
corresponding VLAN IDs associated with each of them.
Table consisting of the VLAN IDs and the corresponding FID
associated with each of them.
Table consisting of the FIDs and the corresponding VLAN IDs
associated with each of them.
Configure Switching Information