A.18 Defaults by Drive Model and Duty Rating ND/HD
A.18 Defaults by Drive Model and Duty Rating ND/HD
The following tables show parameters and default settings that change with the drive model selection (o2-04) and drive duty
selection (C6-01).
Table A.5 400 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
Constant
Name
No.
Model Type
C6-01
ND/HD Select
o2-04
Drive Model Selection
Inverter Rated Current
E2-11
Motor Rated Power
(E4-11)
b3-04
V/f Gain during Speed Search
Output Current 1 during
b3-06
Speed Search
E2-01
Motor Rated Current
(E4-01)
E2-02
Motor Rated Slip
(E4-02)
E2-03
Motor No-Load Current
(E4-03)
E2-05
Motor Line-to-Line
(E4-05)
Resistance
E2-06
Motor Leakage Inductance
(E4-06)
E2-10
Motor Iron Loss for Torque
(E4-10)
Compensation
Momentary Power Loss Ride-
L2-02
Through Time
Momentary Power Loss
L2-03
Minimum Baseblk Time
Momentary Power Loss
L2-04
Voltage Recovery Time
L8-02
Overheat Alarm Level
Carrier Frequency Reduction
L8-38
Selection
Table A.6 575 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
Constant
Name
No.
Model Type
C6-01
ND/HD Select
o2-04
Drive Model Selection
Inverter Rated Current
E2-11
Motor Rated Power
(E4-11)
b3-04
V/f Gain during Speed Search
Output Current 1 during
b3-06
Speed Search
E2-01
Motor Rated Current
(E4-01)
E2-02
Motor Rated Slip
(E4-02)
E2-03
Motor No-Load Current
(E4-03)
E2-05
Motor Line-to-Line
(E4-05)
Resistance
310
Unit
4200
HD
ND
HD
177
177
178
(B1H)
(B1H)
(B2H)
A
414.0
466.0
800.0
KW
200.00
250.00
400.0
%
60
60
60
0.7
0.7
0.7
A
400.0
400.0
800.0
Hz
0.50
0.50
0.50
A
80.0
80.0
160.0
12.000
12.000
8.500
%
20.0
20.0
20.0
W
0
0
0
s
2.0
2.0
2.0
s
2.0
2.0
2.1
s
1.0
1.0
1.0
°C
125
125
125
2
2
2
Unit
5300
HD
ND
HD
225
225
226
(E1H)
(E1H)
(E2H)
A
414.0
466.0
800.0
KW
300.0
335.00
600.0
%
80
80
80
0.5
0.5
0.5
A
350.0
350.0
700.0
Hz
0.5
0.5
0.5
A
70.0
70.0
140.0
14.000
14.000
10.000
YASKAWA ELECTRIC SIEP YEAHHP 01B YASKAWA AC Drive – A1000 HHP Programming Manual
Default Settings
4400
4600
ND
HD
ND
178
179
179
(B2H)
(B3H)
(B3H)
900.0
1200.0
1350.0
500.0
600.0
750.0
60
60
60
0.7
0.7
0.7
800.0
1200.0
1200.0
0.50
0.50
0.50
160.0
240.0
240.0
8.500
7.000
7.000
20.0
20.0
20.0
0
0
0
2.0
2.0
2.0
2.1
2.1
2.1
1.0
1.0
1.0
125
125
125
2
2
2
Default Settings
5600
5900
ND
HD
ND
226
227
227
(E2H)
(E3H)
(E3H)
900.0
1200.0
1350.0
670.0
900.0
1005.0
80
80
80
0.5
0.5
0.5
700.0
1050.0
1050.0
0.5
0.5
0.5
140.0
210.0
210.0
10.000
8.000
8.000
4800
410C
HD
ND
HD
180
180
181
(B4H)
(B4H)
(B5H)
1600.0
1800.0
2000.0
800.0
1000.0
1000.0
60
60
60
0.7
0.7
0.7
1800.0
1800.0
2000.0
0.50
0.50
0.50
360.0
360.0
400.0
6.000
6.000
5.500
20.0
20.0
20.0
0
0
0
2.0
2.0
2.0
2.1
2.1
2.1
1.0
1.0
1.0
125
125
125
2
2
2
5C00
5F00
HD
ND
HD
228
228
229
(E4H)
(E4H)
(E5H)
1600.0
1800.0
2000.0
1200.0
1340.0
1500.0
80
80
80
0.5
0.5
0.5
1400.0
1400.0
1750.0
0.5
0.5
0.5
280.0
280.0
350.0
7.000
7.000
6.000
ND
181
(B5H)
2250.0
1250.0
60
0.7
2500.0
0.50
500.0
5.000
20.0
0
2.0
2.1
1.0
125
2
ND
229
(E5H)
2250.0
1675.0
80
0.5
1750.0
0.5
350.0
6.000