Delete Cfm Mep - D-Link xStack DGS-3620 Reference Manual

Hide thumbs Also See for xStack DGS-3620:
Table of Contents

Advertisement

xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
characters.
ma_index - Specifies the maintenance association index.
<uint 1-4294967295> - Enter the maintenance association index value here. This value
must be between 1 and 4294967295.
state - Specifies the MEP administrative state. The default is disable.
enable - Enable MEP.
disable - Disable MEP.
ccm - Specifies the CCM transmission state. The default is disable.
enable - Enable the CCM transmission.
disable - Disable the CCM transmission.
pdu_priority - The 802.1p priority is set in the CCM and the LTM messages transmitted by the
MEP. The default value is 7.
<int 0-7> - Enter the value between 0 and 7.
fault_alarm - This is the control types of the fault alarms sent by the MEP. The default value is
none.
all - All types of fault alarms will be sent.
mac_status - Only the fault alarms whose priority is equal to or higher than "Some Remote
MEP MAC Status Errors" are sent.
remote_ccm - Only the fault alarms whose priority is equal to or higher than "Some Remote
MEPs Down" are sent.
error_ccm - Only the fault alarms whose priority is equal to or higher than "Error CCM
Received" are sent.
xcon_ccm - Only the fault alarms whose priority is equal to or higher than "Cross-connect
CCM Received" are sent.
none - No fault alarm is sent.
alarm_time - Specifies the time that a defect must exceed before the fault alarm can be sent.
The unit is centiseconds. The default value is 250.
<centisecond 250-1000> - Enter the time that a defect must exceed before the fault alarm
can be sent. The unit is centiseconds. The range is 250 to 1000.
alarm_reset_time - Specifies the dormant duration time before a defect is triggered before the
fault can be re-alarmed. The unit is centiseconds. The default value is 1000.
<centisecond 250-1000> - Enter the dormant duration time before a defect is triggered before
the fault can be re-alarmed. The unit is centiseconds. The range is 250 to 1000.
Restrictions
Only Administrators, Operators and Power-Users can issue this command. (EI Mode Only
Command)
Example
To configure the parameters of an MEP:
DGS-3620-28PC:admin#config cfm mep mepname mep1 state enable ccm enable
Command: config cfm mep mepname mep1 state enable ccm enable
Success.
DGS-3620-28PC:admin#
15-7

delete cfm mep

Description
This command is used to delete a previously created MEP.
239

Advertisement

Table of Contents
loading

Table of Contents