D-Link xStack DGS-3620 Reference Manual page 873

Hide thumbs Also See for xStack DGS-3620:
Table of Contents

Advertisement

xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
enable - Specifies to enable event notification.
disable - Specifies to disable event notification.
remote_loopback - Specifies remote loop.
start - If start is specified, it will request the peer to change to the remote loopback mode.
stop - If stop is specified, it will request the peer to change to the normal operation mode.
received_remote_loopback - Specifies receive remote loop-back.
process - Specifies to process the received Ethernet OAM remote loopback command.
ignore - Specifies to ignore the received Ethernet OAM remote loopback command. The
default method is"ignore".
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure Ethernet OAM on ports 1 to 2 in active mode:
DGS-3620-28PC:admin#config ethernet_oam ports 1-2 mode active
Command: config ethernet_oam ports 1-2 mode active
Success.
DGS-3620-28PC:admin#
To enable Ethernet OAM on port 1:
DGS-3620-28PC:admin#config ethernet_oam ports 1 state enable
Command: config ethernet_oam ports 1 state enable
Success.
DGS-3620-28PC:admin#
To configure the error symbol threshold to 2 and period to 1000ms for port 1:
DGS-3620-28PC:admin#config ethernet_oam ports 1 link_monitor error_symbol
threshold 2 window 1000 notify_state enable
Command: config ethernet_oam ports 1 link_monitor error_symbol threshold 2
window 1000 notify_state enable
Success.
DGS-3620-28PC:admin#
To configure the error frame threshold to 2 and period to 1000 ms for port 1:
DGS-3620-28PC:admin#config ethernet_oam ports 1 link_monitor error_frame
threshold 2 window 1000 notify_state enable
Command: config ethernet_oam ports 1 link_monitor error_frame threshold 2
window 1000 notify_state enable
Success.