xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
To enable the warning temperature log state:
DGS-3620-28PC:admin#config temperature log state enable
Command: config temperature log state enable
Success.
DGS-3620-28PC:admin#
2-11

config temperature threshold

Description
This command is used to configure the warning temperature high threshold or low threshold. When
temperature is above the high threshold or below the low threshold, SW will send alarm traps or
keep the logs.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}(1)
Parameters
high - Specifies the high threshold value. The high threshold must bigger than the low threshold.
<temperature -500-500> - Enter the high threshold value. This value must be between -500
and 500.
low - Specifies the low threshold value.
<temperature -500-500> - Enter the low threshold value. This value must be between -500
and 500.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure a warming temperature threshold high of 80:
DGS-3620-28PC:admin#config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3620-28PC:admin#
2-12
show serial_port
Description
This command is used to display the current console port setting.