Avaya g700 Installation And Upgrades page 392

Media gateway and media server
Hide thumbs Also See for g700:
Table of Contents

Advertisement

Telephones and adjunct systems
To administer CDR parameters
1. Type change system-parameters cdr and press RETURN.
The CDR System Parameters screen appears.
change system-parameters cdr
Node Number (Local PBX ID):
Primary Output Format: unformatted
Secondary Output Format: unformatted Secondary Output Endpoint: CDR2
Modified Circuit ID Display? n
Suppress CDR for Ineffective Call Attempts? y
Disconnect Information in Place of FRL? n
Force Entry of Acct Code for Calls Marked on Toll Analysis Form? n
Record Called Vector Directory Number Instead of Group or Member? n
Inc Trk Call Splitting? n
Record Non-Call-Assoc TSC? n
Record Call-Assoc TSC? n
Privacy - Digits to Hide: 0
2. In the Primary Output Format field, enter a format specific to the call accounting system, if
necessary.
In the example, unformatted is used. If you were sending data directly to a printer, you
would use printer.
3. In the Primary Output Endpoint field, type CDR1.
4. If you use a secondary output device, and that device is also connected through TCP/IP,
complete the Secondary Output Format field.
Also, type CDR2 in the Secondary Output Endpoint field.
5. Press ENTER to save your changes.
392 Installation and Upgrades for Avaya G700 Media Gateway and Avaya S8300 Media Server
Use ISDN Layouts? n
Use Enhanced Formats? n
Record Outgoing Calls Only? y
Record Called Agent Login ID Instead of Group or Member? n
CDR SYSTEM PARAMETERS
Primary Output Endpoint: CDR1
Condition Code 'T' for Redirected Calls? n
Remove # From Called Number? n
Calls to Hunt Group - Record: member-ext
Digits to Record for Outgoing Calls: dialed
CDR Account Code Length: 4
Page
1 of
CDR Date Format: month/day
EIA Device Bit Rate: 9600
Intra-switch CDR? n
CDR Call Splitting? y
Attendant Call Recording? y
Interworking Feat-flag? n
1