Page 1
Quick Start Avaya™ S8300 Media Server and Avaya™ G700 Media Gateway Hardware Installation Get License File, Software, and Firmware Conduct Equipment Inventory Mount Media Gateway (Optional) Install Octaplane Stacking Module (Optional) Connect Media Gateways (Optional) Install S8300 Media Server Install Media and Expansion Modules...
Page 2
All trademarks identified by the ® or ™ are registered trademarks or trademarks, respectively, of Avaya Inc. All other trademarks are the property of their respective owners. Copyright 2002, Avaya Inc. All rights reserved.
WARNING: The Avaya G700 Media Gateway must not be operated with any slots open. Empty slots should be covered with the supplied blank plates. Grounding...
Page 4
Laser components used in the G700 are Class 1 Laser Products that comply with 21CFR 1040.10 and CFR 1040.11. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Contact your Avaya representative for more laser product information. Luokan 1 Laserlatte...
Page 5
Get License File, Software, and Firmware Get License File, Software, and Firmware The following activities must take place before you can install an Avaya S8300 Media Server with an Avaya G700 Media Gateway: • A meeting is held with the customer to complete the Preinstallation Worksheet. The Preinstallation Worksheet contains specific information about the customer’s network configuration and...
Page 6
Once you have verified that all activities are completed, you can begin product hardware installation following instructions in this Quick Start Avaya™ S8300 Media Server and Avaya™ G700 Media Gateway Hardware Installation guide. Note: The laptop PC that you use to launch the Avaya Installation Wizard must meet the following requirements: •...
Conduct Equipment Inventory ALM PWR CPU MSTR LNK COL Tx FDX FC Hspd LAG EXT1 EXT2 Avaya G700 Media Gateway EXT1 EXT2 Avaya S8300 Media Server SHUT DOWN OK TO REMOVE SERVICES USB1 USB2 Avaya MM710 T1/E1 Media Module E1/T1...
Page 8
Conduct Equipment Inventory Expansion Module X330T16 X330STK Octaplane Stacking Module X330SC Short Cable Note: The X3300SC Short Cable is sometimes shipped attached to the X3300STK Octaplane Stacking Module. X3300RC Redundancy Cable X3300 LC Long Cable...
Page 9
Conduct Equipment Inventory USB Cable and Adapter Crossover Ethernet Cable (CAT5) Serial or "Console" Cable and Adapter...
Page 10
Conduct Equipment Inventory Uninterruptable Power Supply (UPS), Optional Note: A Stand-alone version of the Uninterruptable Power Supply (UPS) is shown. Screw Packet and Rack Mount Brackets Note: .There are four sizes of lock- washer screws in the packet for attaching the brackets to the rack. Use the appropriate size screws to match the specific hole size of the rack.
Page 11
Conduct Equipment Inventory Anti-Static Wrist Ground Strap (ESD) Note: The Anti-Static Wrist Ground Strap (ESD) is not shipped with the product and must be supplied by the technician. Power Cord Feet...
Mount Media Gateway Wear an anti-static ground wrist strap and attach to an approved ground. For rack mount, install the mounting brackets using flathead screws from the screw packet. Lift media gateway and mount in a rack. DANGER • The weight of the media gateway is unevenly distributed and may require two persons to mount in the rack.
Page 14
Mount Media Gateway EXT1 EXT2 ALM PWR CPU MSTR LNK COL Tx FDX FC Hspd LAG For desktop mount. Install feet using plastic push rivets. EXT1 EXT2 Lift media gateway and place on desktop. DANGER • The weight of the media gateway is unevenly distributed and may require two persons to lift and place on the desktop.
Install Octaplane Stacking Module Note: Complete this step only if you are connecting more than one G700 Media Gateway in a stack configuration. From the back of the media gateway, remove the blank faceplate from the media module slot. Align the X330STK Octaplane Stacking Module with the interior guides and insert until firmly seated WARNING...
Connect Media Gateways Note: Complete this step only if you are connecting more than one G700 Media Gateway in a stack configuration. Using the gray X330SC short cables, connect the media gateways from the bottom up: • Connect the light gray connector to the port labeled “Cable to upper unit.”...
Page 18
Connect Media Gateways For multiple stack redundancy, connect the stacks using the black X330RC redundancy cable and the gray X330LC long cable: • Connect the light gray connector of the black X330RC redundancy cable to the port labeled “Cable to upper unit” on the top unit of the stack 2.
Remove the LED module and place in an anti-static bag. Optional. Using the instructions packaged with the IA770 Messaging Module, attach the IA770 module to the S8300 Media Server. Align the S8300 Media Server with the lower interior guides and insert about 2" into slot V1.
Page 20
Install S8300 Media Server Align the LED module with the upper interior guides and insert until the faceplate is flush with the S8300 Media Server. Continue inserting both modules together until firmly seated. WARNING Failure to seat both modules together could result in equipment damage.
Note: I n each gateway, a single expansion module may be installed. The expansion module can be installed in the lower left slot only. If the S8300 is installed, a maximum of 3 media modules can be installed in each gateway. In this case, media modules can be installed in the right slots only, starting from the top.
Page 22
Install Media and Expansion Modules Optional. For installation of the expansion module, from the front of the G700 Media Gateway remove the lower left blank faceplate. Align the expansion module with the interior guides and insert into slot until firmly seated. Tighten the captive screws.
Page 23
Install Modem From the front of the S8300 Media Server, connect the USB cable to either USB port. Following the instructions packaged with the modem, connect the other end of the USB cable to the modem. Connect the analog telephone line to...
Page 25
Install UPS Optional. From the back of the G700 Media Gateway, connect the UPS using the manufacturer’s instructions. Note: A stand-alone version of the Uninterruptable Power Supply (UPS) is shown.
Page 29
Verify the Services network settings: a. IP Address: 192.11.13.5 b. Subnet Mask: 255.255.255.252 c. Domain Name Service (DNS): disabled. Open MS Internet Explorer and disable the Proxy Server. In the browser address field, initiate access to the S8300 by typing in lower case: http://192.11.13.6...
Page 30
Click OK or Yes, as appropriate, for any security pages that may appear prior to the Logon page. Log in to the S8300 Media server with the craft login and password for initial installation. If you are using the Avaya Installation Wizard, click on Launch Avaya Installation Wizard and continue.