(6) Push the pin of the positioning plate into the
connecting part of the PZ-108 and Finisher, and
temporarily secure the positioning plate with
screws. (TP screw M4x6: 2 pcs.)
Positioning plate
(FS-108/108B/108BM)
Positioning plate
TP screws
M4x6
(FS-111/211)
IV. Installation procedure for main body
1. Turn the power to the main body OFF, then unplug
the power cord from the power outlet.
2. Install the main body installation stay on the upper
left side of the main body. (TP screw M4x18: 2
pcs. <Finisher accessory parts>)
Caution:
If the Finisher has been installed on the main body,
remove the main body installation plate (upper)
<Finisher accessory part> from the upper-left side
of the main body, then perform Step 2. ( TP screw
M4x18: 2 pcs.)
TP screws M4x6
E-4
3. Remove the installation plate (1 screw) from the
main body installation plate (upper) <Finisher
accessory part>, then install it on the main body
installation stay (1 screw).
Installation plate
TP screws M4x18
<Finisher accessory parts>
4. Install the main body installation plate (lower)
<Finisher accessory part> on the lower left side of
the main body. (TP screw M4x6: 2 pcs. <Finisher
accessory parts>)
Caution:
If the Finisher has been installed on the main body,
use the main body installation plate (lower) as-is.
Main body installation plate (lower)
TP screws M4x6
<Finisher accessory parts>
5. Connect the two PZ-108 connectors to the
connectors on the rear paper-exit side of the main
body.
PZ-108 connectors
Main body instllation stay
Main body connectors
(Large connector)