Adjustment Data Display; Hard Disk Check - Konica Minolta 7085/FORCE 85 Service Manual

Konica 7075/force 75; 7085/force 85
Table of Contents

Advertisement

[2] Adjustment Data Display

Displaying a list of machine adjustment values
(factory-set values and current values).
No adjustment (data value change) can be made
in this mode.
Step
1
Enter the 47 mode.
2
[I/O Check Mode Screen]
Enter 94 with numeric keys.
Make sure 94 is displayed in the message
display field.
3
Press the Start button.
4
[Adjustment Data Display Screen]
Press the
desired adjustment item.
5
To return to the I/O Check Screen, press
the
key to return to the I/O Check
EXIT
Mode Screen.

[3] Hard Disk Check

Execute this adjustment to check the total ca-
3
pacity or the remaining capacity of the optional
(7075) or the standard (7085) hard disk, and
when error code related to the hard disk is de-
tected.
Step
1
Enter the 47 mode.
2
Enter 99 with numeric keys.
3
(1) Checking the total capacity of the hard
disk
Press the P button and enter 1 with a
numeric key. Make sure 99-01 is dis-
played in the message display field.
(2) Checking the remaining capacity of the
hard disk
Press the P button and enter 2 with a
numeric key. Make sure 99-02 is dis-
played in the message display field.
(3) Checking and recovering bad sectors
on the hard disk
Press the P button and enter 3 with a
numeric key. Make sure 99-03 is dis-
played in the message display field.
4
Press the Start button.
MODEL
7075/7085
SERVICE HANDBOOK
Operation
or
button to display a
Operation
MANUAL
REVISED EDITION
5
(1) When the total capacity of the hard
disk is checked
The total capacity of the hard disk is
displayed after "OUT:" in the message
display field.
(2) When the remaining capacity of the
hard disk is checked
The remaining capacity of the hard
disk is displayed after "OUT:" in the
message display field.
(3) When bad sectors on the hard disk
are checked and recovered
"NOW" is displayed after "OUT:" in the
message display field and bad sector
check and recovery start. Several
minutes later, "OK" is displayed in the
case of normal termination; "NG" is
displayed in the case of abnormal
termination.
When "NG" is displayed, retry bad
sector check and recovery. If "NG" is
displayed again, replace the hard disk.
Note 1: Once the bad sector check and
Note 2: The had disk is weak against vi-
DATE
1 - 97
Jan. 2002
3
47 ADJUSTMENT
recovery procedure start, it can
not be canceled. (The Stop
button and mode change key are
ineffective.)
bration and shock. When mov-
ing the copy machine, be sure to
remove the hard disk in advance.
PAGE
METHOD
1-97
REPLACEMENT