OTHER ADJUSTMENT

[16] FNS Adjusting the By-pass Gate

1. Tools used
• Screwdriver (Phillips)
• Scale
2. Preparation
(1) Remove the rear cover.
(2) Open the front cover and the guide plate.
(3) Remove the 2 set screws holding the FNS CB in
place. Remove the FNS CB together with its
bracket.
Bracket
MODEL
7075
SERVICE HANDBOOK
Guide Plate
FNS CB (Finisher Control Board)
Screws
MANUAL
REVISED EDITION
(4) Remove the wirings from the clamps, and move
the FNS CB together with its bracket.
Clamps
Clamp
(5) With SD5 (by-pass) OFF, measure the distance
between the by-pass gate and the guide plate,
indicated by A in the illustration.
Spec value for distance: A = 4.3±0.5mm
(6) With SD5 ON, measure the gap between the
solenoid plunger and the bracket stopper (indi-
cated by B in the illustration).
Spec value for gap: B = 5±0.5mm
SD5 (By-pass)
Guide Plate
(7) If either measurement is out of spec, carry out
adjustment as described below.