[9] Removing and Reinstalling the
Plunger Prevention Plate
Caution: Be sure the power cord has
been unplugged from the wall
outlet.
a.
Procedure
(1) Open the toner supply unit. (See "TONER SUP-
PLY UNIT.")
(2) Draw the ADU frame out of the main body. (See
"ADU UNIT.")
(3) Remove the transfer/separation corona unit.
(4) Release 12 (7075) or six (7085) locks and detach
3
the plunger prevention plate (7075) or the plunger
prevention plate (front) (rear) (7085).
Plunging prevention
plate (rear) (7085)
Locks
(the same number of locks
on the opposite side)
(5) Reinstall the above parts following the removal
steps in reverse.
Caution: Make sure that the loking claws are
securely fit into the backplate holes.
MODEL
7075/7085
SERVICE HANDBOOK
Plunging prevention
plate (7075)
Plunging prevention
plate (front) (7085)
MANUAL
REVISED EDITION
[10] Replacing the Transfer/Separation
Wires, Transfer/Separation Wire
Cleaning Block and Support
Rubbers
Caution: Be sure the power cord has
a.
Procedure
(1) Open the toner supply unit. (See "TONER SUP-
PLY UNIT.")
(2) Draw the ADU frame out of the main body. (See
"ADU UNIT.")
(3) Remove the transfer/separation corona unit.
(4) Remove the plunger prevention plate.
(5) Remove the spark arrester plates (front and
rear).
Spark arrester plate (rear)
(6) Remove the springs of wires (one each) to re-
move the wires.
Caution: When installing the springs, bend the
edge of each spring in side.
DATE
3 - F - 5
Jan. 2002
3
CORONA UNIT SECTION
been unplugged from the wall
outlet.
Spark arrester plate (front)
PAGE
METHOD
3-F-5