25 ADJUSTMENT
3.
Setting KRDS software SW
3
This function sets KRDS software switch.
Caution: Set the software switch while checking
the switch and bit number since the
memory is rewritten every time the bit
data (1 or 0) is changed.
Any bit data that has been incorrectly
changed must be returned to the
original data.
[KRDS Software Switch Setting Screen]
Switch number
Bit number (0-7)
Step
1
Enter the 25 mode.
2
[25 Mode Menu Screen]
Press
KRDS setting.
10
3
[KRDS Setting Screen]
Press
KRDS software switch setting.
4
4
[KRDS Software Switch Setting Screen]
Use
,
number.
(See *1.)
5
Use
,
, or ten keys to set the bit number.
6
Press
or
ON
7
Press
PREVIOUS SCREEN
(See *2.)
*1: For the function of each switch, refer to "List of
KRDS Software DIP Switches".
*2: The bit data will be written in the non-volatile RAM
every time it is changed.
MODEL
7075/7085
SERVICE HANDBOOK
Bit data
Operation
, or ten keys to set the switch
key to set the bit data.
OFF
key to end setting.
MANUAL
REVISED EDITION
(1) Setting type of modem and line
• Using the switch No. 01, enter the modem and
line data into the bits 0 to 7, referring to the
following table.
<Type of line: Pulse>
Bit No.
Type of
Modem Command
AT&FE0Q0V1X0S0
=1&S0
AT&FE0Q0V1X0S0
=1&S0&D2&C1
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0%E0
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0&D2
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0&M5
<Type of line: Tone>
Bit No.
Type of
Modem Command
AT&FE0Q0V1X0S0
=1&S0
AT&FE0Q0V1X0S0
=1&S0&D2&C1
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0%E0
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0&D2
AT & F E 0 Q 0 V 1 X 0 S 0
=1&S0&M5
Example:Enter 00000001 for all of the bit Nos.7-0 if
the type of the modem command is
AT&FE0Q0V1X0S0 =1&S0 and the type
of line is Pulse. The hexadecimal value
is indicated as 01. Check if the
hexadecimal value corresponds with
the specified modem according to the
above table.
Note :
If the KRDS DIP switch 38-0 is set to
1 (ON), the KRDS DIP switch 1-7 for
pulse/tone selection is not effective.
Check that the KRDS DIP switch
38-0 is set to 0 (OFF) before selecting
the KRDS DIP switch 1-7.
DATE
1 - 50
Jan. 2002
3
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 1 01
0 0 0 0 0 0 1 0 02
0 0 0 0 0 0 1 1 03
0 0 0 0 0 1 0 0 04
0 0 0 0 0 1 0 1 05
7 6 5 4 3 2 1 0
1 0 0 0 0 0 0 1 81
1 0 0 0 0 0 1 0 82
1 0 0 0 0 0 1 1 83
1 0 0 0 0 1 0 0 84
1 0 0 0 0 1 0 1 85