36 ADJUSTMENT
6.
RADF restart timing adjustment
Adjusting the scanner restart timing during RADF
copy.
Caution: Printer restart timing adjustment must
be completed before performing this
adjustment.
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press "
Image adjustment."
2
3
[Image adjustment mode menu Screen]
Press "
Timing adjustment."
3
4
[Timing adjustment mode menu Screen]
Press "
RADF restart timing adjustment."
6
5
[RADF restart timing adjustment
Screen]
Press the
COPY SCREEN
6
Select A3-size paper, set an adjustment
chart on RADF, and press the Start but-
ton.
7
Check the leading edge timing on front
and back side.
Specification: within 3 mm
8
If the leading edge timing is not appro-
priate, press the C button while press-
ing the P button.
9
[RADF restart timing adjustment
Screen]
Press the
NEXT ADJUSTMENT
PREVIOUS ADJUSTMENT
item to be adjusted.
The screen changes from SIDE1 to
SIDE2.
10
Enter a value with the numeric keys and
3
press the
SET
Setting range: -60 to +50 (7075)
Setting range: -50 to +50 (7085)
1 step=0.1 mm
11
Repeat steps 5 to 10 until the leading
edge timing is within specification.
12
Press the
PREVIOUS SCREEN
turn to the Timing adjustment mode
menu Screen.
MODEL
7075/7085
SERVICE HANDBOOK
Operation
key.
or
key to select the
key.
key to re-
MANUAL
REVISED EDITION
7.
RADF regist loop adjustment
Adjusting the regist loop amount during RADF
copy.
Caution: Printer restart timing adjustment must
be completed before performing this
adjustment.
Step
1
Enter the 36 mode.
2
[36 Mode Menu Screen]
Press "
3
[Image adjustment mode menu Screen]
Press "
4
[RADF regist loop adjustment Screen]
Press "
5
Press the
switch to Both side - Single side copy
mode.
6
Select A3-size paper, set adjustment
chart on RADF, and press the Start but-
ton.
7
Check the loop amounts on the front and
back sides.
8
If the registration loop amount is not ap-
propriate, press the C button while press-
ing the P button.
9
[RADF resist loop adjustment Screen]
Press the
PREVIOUS ADJUSTMENT
item to be adjusted.
The screen changes from SIDE1 to
SIDE2.
10
Enter a value with the numeric keys and
press the
Setting range: -10 to +10
1 step=0.5 mm
11
Repeat steps 5 to 11 until the registra-
tion loop amount is within specification.
12
Press the
turn to the Timing adjustment mode
menu Screen.
DATE
1 - 80
Jan. 2002
3
Operation
Image adjustment."
2
Timing adjustment."
3
RADF restist loop adjustment."
7
key and then
COPY SCREEN
or
NEXT ADJUSTMENT
key to select the
key.
SET
key to re-
PREVIOUS SCREEN
PAGE
METHOD
1-80