[8] RADF Mounting Position Adjustment

1.
Tool
• Screwdriver (Phillips)
2.
Adjustment method
Adjusting screw B
Step
1
Close the RADF.
2
Check whether both stopper pieces on
the RADF side touch the slit glass.
Caution: The state of contact between
Top cover
(middle)
Slit
Adjusting screw A
Operation
the stopper pieces and the silt
glass can be checked by
looking into the slits in the top
cover (middle) of the main unit.
Stopper
piece
Stopper
piece
Slit glass
Slit
3
If both stopper pieces do not touch the
slit glass, make adjustments using ad-
justing screws A and B alternately.
4
Perform steps 2 and 3 repeatedly until
the two stopper pieces touch the slit
glass at the same time.